9032-OM (V4.1) 9032 PRODUCT MANUAL 3-29
Operating Instructions Troubleshooting
DashBoard shows
Framesync Status error
message in 9032 Framesync
function submenu screen.
Specified Minimum Latency
Frames setting exceeds 9032
card buffer space for the
selected output video format
Reduce the Minimum Latency Frames setting
as specified in the error message to correct the
error.
Note:
Due to card memory limits, the maximum
available Minimum Latency Frames is
related to the output video format selected.
For example, with a 1080i 5994 output, the
maximum setting is 5. For a 1080i film
(2398) output, the maximum setting is 3
(due to the increased buffer space needed
for the slower frame rate). Conversely,
greater maximum settings are allowed for
SD formats such as 525i 5994, where the
practical maximum limit is 13.
DashBoard shows Output
Status error message in 9032
Timecode function submenu
screen.
Timecode not available due to
lack of appropriate input
timecode data
Timecode output requires that source and
priority are appropriately selected. Also, video
input must contain appropriate timecode data
and framesync reference.
Refer to Timecode function submenu tab on
page 3-16 for more information.
Unsmooth, jerky motion
observed on video output with
Framesync set to lock to input
video.
Incompatible negative H/V
delay value user setting of
Vertical Delay or Horizontal
Delay controls
Negative vertical or horizontal delay values
(using the controls below) should not be used
when using Input Video mode. To add an offset
in this case, instead apply a positive value that
results in the desired net offset.
Analog VITC waveform timecode
not received and/or processed.
Card erroneously set for NTSC
signal with 0 IRE of setup with
input containing setup
If analog VITC timecode source contains
7.5 IRE of setup, make certain
Video Signal Controls > NTSC Contains is
set to 7.5 IRE of Setup.
If this is not done, analog VITC waveform may
not be received and processed by the card.
Ancillary data (closed captioning,
timecode, AFD) not transferred
through 9032.
Control(s) not enabled Make certain respective control is set to On
or Enabled (as appropriate).
VANC line number conflict
between two or more
ancillary data items
Make certain each ancillary data item to be
passed is assigned a unique line number
(see Ancillary Data Line Number Locations
and Ranges on page 3-8).
Table 3-4 Troubleshooting Processing Errors by Symptom continued
Symptom Error/Condition Corrective Action