Operator`s manual

CrossOver 16 User Manual (v4.0) Specifications • 9–3
Read Analog MLE/Keyer 3 45 <control>
Write Analog MLE/Keyer 5 C5 <control> <lsb> <msb>
Read Light On/off MLE/Keyer 3 46/47
Write Light On/off MLE/Keyer 3 C6/C7 <lamp>
Read Wipe Pattern MLE 2 48
Write Wipe Pattern
MLE 3 C8 <wipe> Valid wipes are 0-9, as
per the Wipe Pattern
button numbers. An
invalid wipe number
returns a protocol error.
Read Transition Mode MLE 2 4A
Write Transition Mode
MLE 3 CA <mode> Last 5 bits used; bit 0:
key 1, 1: key 2, 3: bkgd,
4: key 3, 5: key 4
Read Mle Autotrans Rate MLE 2 4C
Read Keyer Mix Rate Keyer 2 4D
Read Fade To Black Rate MLE* 2 7D *Currently MLE-specific
Write Mle Autotrans Rate MLE 5 CC **
Write Keyer Mix Rate Keyer 5 CD **
Write Fade To Black Rate
—* 5 FD ** *Currently not supported.
Fade to black = transition
rate.
Read Key Settings Keyer 2 53 Not yet implemented
Write Key Settings Keyer 62(?) D3 Not yet implemented
Learn Into Mem 3 DA <mem#> Supports memories 0-9
Recall From Mem 3 DB <mem#> Supports memories 0-9
Read Software Version 2 6C
Read Field Mode 2 6D Field Mark only
Write Field Mode 2 ED 0 or 1 Field Mark only
All Stop 3 F2 D0* *Data byte is unused
Read Lamp Status 3 78 0
Write Lamp Status
3 F8 Included for GVG100
spec completeness only.
Write Button Press Both 3 FB <button>
Send Mem To Editor 3 7E Not yet implemented
Load Mem From Editor 73 FE Not yet implemented
Table 9.2 GVG100 Supported Commands
Name MLE/Keyer Length Byte Code Data/Notes