User manual

CrossOver 6 / 12 User Manual (v1.4) Specifications • 6–5
Key Bus On Air Keyer 0x2A Turning OFF results in a protocol error.
Key Video Fill
Keyer 0x2F Always true. Turning OFF results in a
protocol error.
Wipe Type MLE 0x30-0x39 Turning OFF results in a protocol error.
Key Invert
Keyer 0x40 DSKs. Turning OFF results in a protocol
error.
Key Mask
Keyer 0x41 DSKs. Turning OFF results in a protocol
error.
Key Autokey
Keyer 0x42 DSKs. Turning OFF results in a protocol
error.
Key Selfkey
Keyer 0x43 DSKs. Turning OFF results in a protocol
error.
Key Invert Keyer 0x44 Turning OFF results in a protocol error.
Key Mask Keyer 0x45 Turning OFF results in a protocol error.
Memory Mode Toggle
0x47 Toggles between memory and pattern
modes.
Next Trans Is Bkgd 0x48 Turning OFF results in a protocol error.
Next Trans Is Key 1 0x49 Turning OFF results in a protocol error.
Cut MLE 0x4A Turning OFF results in a protocol error.
Key Selfkey Keyer 0x4C Turning OFF results in a protocol error.
Key Autokey Keyer 0x4D Turning OFF results in a protocol error.
Key Chromakey Keyer 0x4E Turning OFF results in a protocol error.
Editor Enable
0x4F Editor control is always enabled.
Turning OFF results in a protocol error.
Keyer Active Keyer 0x52
Table 6.4 GVG100 Supported Buttons
Name MLE/Keyer Byte code Notes
Program Bus 0-9 MLE 0x00-0x09
Autotrans MLE 0x0B
Key Trans Keyer 0x0C DSKs
Key Cut Keyer 0x0D DSKs
Wipe Trans MLE 0x0E
Dissolve Trans MLE 0x0F
Preset Bus 0-9 MLE 0x10-0x19
Aspect MLE 0x1B Always on. Button press has no effect.
Positioner On 0x1C Always on. Button press has no effect.
Reverse Wipe
MLE 0x1D Doubles as memory store/recall toggle
when in memory mode
Table 6.3 GVG100 Supported Lamps
Name MLE/Keyer Byte Code Notes