-2-
attached to an Earth ground (best) or signal
ground connection at the panel or power supply
end of the cable. This configuration is best for
shielding the Reader cable from external
interference.
HOW TO TEST AND OPERATE THE READER
The Reader should be tested after wiring it to a
power supply and the Host. Do this by performing
the following steps:
1. Power up the Reader. The LED and Beeper will
activate three times. This indicates that the
Reader is working properly.
2. Present the appropriate type of ID card to the
Reader. (See Table 1 for the correct card type
based on the reader model.) The LED should
momentarily flash green and a short beep will
be emitted. This indicates that the card was
read properly by OmniProx and this LED flash
and beep is generated by the Reader.
3. After the card data is processed by the Host,
the Host can then turn the LED green or yellow.
Refer to the Host description of the LED
operation if the Reader LED is controlled by the
Host.
Table 1: Part Number vs. Feature Matrix
Model
Number
Card
Type
Output
Format
Read
Range
(Max.)
*
OP10-FWc HID Wiegand 3”
OP11-AWc ADEMCO Wiegand 3”
OP20-FWc HID Wiegand 4”
OP21-AWc ADEMCO Wiegand 4”
OP30-FWc HID Wiegand 5”
OP31-AWc ADEMCO Wiegand 5”
OP40-FWc HID Wiegand 4”
OP41-AWc ADEMCO Wiegand 4”
Last character of Omniprox P/N indicates color; B
= Black, G = Gray, W = White, etc.
* Measured using HID Corp. Prox Card II (P/N
1326LSSMV) or equivilent. Range also depends on
electrical environment and/or proximity to metal.
OmniProx models with HID
compatibility are capable of
reading genuine HID cards
under the terms of a license
agreement between HID Corp.
and the ADEMCO Group.