User's Manual
-3-
Model
Number
UL Listing
Part #
Card
Type
Output
Format
Read
Range
(Max.)
*
OP45-FW AY-M10 HID Wiegand 4”
OP45-AW
AY-M12 ADEMCO
Wiegand 4”
OP90-FW AY-Qxx HID Wiegand 1.5”
*Measured using HID Corp. Prox Card II (P/N 1326LSSMV)
or equivalent and the corresponding OmniProx reader
powered at 12 volts. Range also depends on electrical
environment and/or proximity to metal.
SPECIFICATIONS
Electrical Characteristics:
Power Supply Type:
Linear type Recommended
Operating Voltage Range:
5.0 – 16 VDC (Operational down to 4.25 VDC)
Maximum input current:
OP10, OP20
Standby: 35 mA
Read: 50 mA
OP30, OP40, OP45, OP90
Standby: 35 mA
Read: 100 mA
Tamper Output
Open collector, active low, max.sink current is 16 mA
Maximum Cable Distance to Host:
500 ft. (150 meters)
Card Read Distance:
See Table 2
Regulatory Approvals:
USA: UL 294 Listed & FCC Part 15 B
(Model OP90 is not yet UL listed)
Europe: CE Listed
Operating Temperature Range:
-25° F to 145° F (-31°C to 63°C)
Operating Humidity:
0 to 95% (non condensing)
Suitable for outdoor use
Dimensions:
OP10:
3.15” (80mm) L x 1.58” (40mm) W x 0.50” (12.8mm) D
OP20:
4.73” (120mm) L x 1.65” (42mm) W x 0.55” (14mm) D
OP30:
5.71” (145mm) L x 1.69” (43mm) W x 0.79” (20mm) D
OP40:
4.33” (110mm) L x 2.96” (75mm) W x 0.59” (15mm) D
OP45:
3.5” (89mm) L x 3.5” (89mm) W x 0.59” (15mm) D
OP90:
4.72” (120mm) L x 3” (76mm) W x 1” (27mm) D
For additional information on th
e Wiegand™ Protocol, see
“Access Control Standard –
Wiegand Card Reader Interface
SIA AC-
01 (1996.10)” which can be purchased from SIA (see
www.siaonline.org)
OmniProx models with HID
compatibility are capable of reading
genuine HID cards under the ter
ms
of a license agreement between HID
Corp. and the ADEMCO Group.