Table Of Contents
Technical Specifications
AYC-E/Q60 Family Instruction Manual 11
2. Technical Specifications
Specifications AYC-E/Q60
Electrical Characteristics
Power Supply Type
Linear type – recommended
Operating Voltage Range
5–16 VDC (when used as a controller,
provided by the secured series intelligent
power supply)
Input current standby (12
VDC)
110 mA
Input Current Max (16 VDC)
130 mA
LED Control Input
Dry contact N.O.
Tamper Output
Open collector, active low, 32 mA max sink
current
Cable Distance to Host
Controller
Up to 500 ft (150 meters) using an 18AWG
cable
Max Proximity Card Read
Range*
Rosslare PROX: E40 mm, Q – 45 mm
HID Prox: E – 40 mm, Q 45 mm
Proximity Card Modulation
Rosslare PROX/HID Prox at 125 KHz
Proximity Card
Compatibility
Rosslare PROX/HID Prox cards
Card Transmit Format
(Reader)
Rosslare PROX cards: Wiegand 26-bit, or
Clock & Data
HID cards: According to card type
Keypad Transmit Format
(Reader)
Programmable PIN code formats
LED Indicators
Two tri-colored LEDs
Communication
Data1/C1, Data0/C2open collector, 5 V
termination
* Measured using a Rosslare proximity card (AT-R14) or equivalent.
Range also depends on electrical environment and proximity to