User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Installation
- 4. Wiring Instructions
- 5. Reader Functionality
- 5.1 Transmit Mode
- 5.2 Programming the AYC-E/Q60 Series
- 5.2.1 Entering Programming Mode
- 5.2.2 Exiting Programming Mode
- 5.2.3 Selecting Keypad Transmission Format
- 5.2.4 Keypad Transmission Format Option Number
- 5.2.4.1 Option 1: Single Key, Wiegand 6-Bit (Rosslare Format)
- 5.2.4.2 Option 2: Single Key, Wiegand 6-Bit Nibble and Parities
- 5.2.4.3 Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented
- 5.2.4.4 Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit
- 5.2.4.5 Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
- 5.2.4.6 Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit
- 5.2.4.7 Option 7: Single Key, 3x4 Matrix Keypad (MD-P64)
- 5.2.4.8 Option 8: 1 to 8 Keys BCD, Clock & Data
- 5.2.4.9 Option 9: Single Key, Wiegand 4-Bit
- 5.2.5 Selecting HID Prox Card Transmission Format
- 5.2.6 Selecting Rosslare PROX Card Transmission Format
- 5.2.7 Changing the Programming Code
- 5.2.8 Changing the Facility Code
- 5.2.9 Setting the Backlight Behavior
- 5.2.10 Setting the Reader Format
- 5.2.11 Return to Factory Default Settings
- 5.2.12 Replacing a Lost Programming Code
- 6. Controller Functionality
- 6.1 Normal, Secure, and Master Users
- 6.2 Modes of Operation
- 6.3 Changing the Modes of Operation
- 6.4 Auxiliary Input & Output
- 6.5 Door Alarms
- 6.6 Internal Case and Back Tamper
- 6.7 Lockout Feature (Keypad/Card Tamper)
- 6.8 REX Function
- 6.9 Secured Series Intelligent Power Supply
- 6.10 Programming the AYC-E/Q60
- 6.10.1 Entering Programming Mode
- 6.10.2 Exiting Programming Mode
- 6.10.3 Changing Lock Strike Code
- 6.10.4 Changing Auxiliary Code
- 6.10.5 Changing the Programming Code
- 6.10.6 Changing the Normal/Secure Code
- 6.10.7 Changing the Normal/Bypass Code and Door Chime Settings
- 6.10.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 6.10.9 Defining the Auxiliary Input and Output
- 6.10.10 Detailed Reference Guide
- 6.10.11 Setting the Lockout Feature
- 6.10.12 Setting the Backlight Behavior
- 6.10.13 Selecting the Rosslare PROX and HID Prox Format
- 6.10.14 Enrolling Primary and Secondary Codes
- 6.10.15 Deleting Primary and Secondary Codes
- 6.10.16 Relay Codes Assignment
- 6.10.17 PIN Code Length/Factory Default Settings
- 6.10.18 Replacing a Lost Programming Code
- 6.10.19 Replacing a Lost Normal/Secure Code
Technical Specifications
12 AYC-E/Q60 Family Instruction Manual
Specifications AYC-E/Q60
Environmental Characteristics
Operating Temp. Range
-22°F to 150°F (-30°C to 65°C)
Operating Humidity
0 to 95% (non-condensing)
Outdoor Usage
Weather-resistant, meets IP-65, epoxy
potted, suitable for indoor and outdoor
use
Mechanical
Size
(Height x Width x Depth)
E: 6.10 x 3 x 0.827 in. (155 x 1.73 x 0.35 mm)
Q: 4.72 x 2.99 x 0.83 in. (120 x 76 x 21 mm)
Weight
E: 0.32 lb (143 g)
Q: 1.06 lb (480 g)
2.1 Key Features
The key features for the AYC-E/Q60 series are:
Built-in Proximity Card Reader (125 KHz Rosslare PROX/HID Prox
Modulation)
Programmable blue backlit keypad
Optical back tamper sensor and open collector tamper output
Lockout feature on wrong entry (keypad/card tamper)
Internal buzzer provides audible interface feedback
Two status/programming interface LEDs (tri-colored)
Fully-potted construction for outdoor use
Comes with mounting template for easier installation
Comes with an installation kit that includes a security screw and a
security screw tool