User's Manual
Table Of Contents
- 1. General Information
- 2. Technical Specifications
- 3. Installation
- 4. Wiring Instructions
- 5. Reader Functionality
- 5.1 Transmit Mode
- 5.2 Programming the AYC- F/G/M60 Series
- Programming Menu
- Entering Programming Mode
- Exiting Programming Mode
- Selecting Keypad Transmission Format
- Keypad Transmission Format Option Number
- Option 1: Single Key, 6-Bit Wiegand (Rosslare Format)
- Option 2: Single Key, 6-Bit Wiegand Nibble and Parities
- Option 3: Single Key, 8-Bit Wiegand Nibbles Complemented
- Option 4: 4 Keys Binary + Facility Code, 26-Bit Wiegand
- Option 5: 1 to 5 Keys + Facility Code, 26-Bit Wiegand
- Option 6: 6 Keys BCD and parity bits, 26-Bit Wiegand
- Option 7: Single Key, 3x4 Matrix Keypad (MD-P64)
- Option 8: 1 to 8 Keys BCD, Clock & Data
- Option 9: Single Key, 4-bit Wiegand
- Selecting Proximity Card Transmission Format
- Changing the Programming Code
- Changing the Facility Code
- Setting the Backlight and Reader Format
- Return to Factory Default Settings
- Replacing a Lost Programming Code
- 6. Controller Functionality
- 6.1 Normal, Secure, and Master Users
- 6.2 Modes of Operation
- 6.3 Auxiliary Input & Output
- 6.4 Door Alarms
- 6.5 Internal Case and Back Tamper
- 6.6 Lockout Feature (Keypad / Card Tamper)
- 6.7 Request to Exit (REX) Function
- 6.8 Secure Application Appurtenances
- 6.9 Programming the AYC- F/G/M60
- Programming Menu
- Entering Programming Mode
- Exiting Programming Mode
- Changing Lock Strike Code
- Changing Auxiliary Code
- Changing the Programming Code
- Changing the Normal / Secure Code
- Changing the Normal / Bypass Code and Door Chime Settings
- Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- Defining the Auxiliary Input and Output
- Quick Reference Guide for Auxiliary Mode Setting
- Detailed Reference Guide
- Setting the Lockout Feature
- Setting the backlight behavior
- Enrolling Primary and Secondary Codes
- Deleting Primary and Secondary Codes
- Relay Codes Assignment
- Relay Code Assignment using Search Method
- Pin Code Length / Factory Default Settings
- Replacing a Lost Programming Code
- Replacing a Lost Normal / Secure Code
![](/manual/rosslare-enterprises/ayc-f60/user-s-manual-english/images/img-44.png)
opened, the controller will wait for the door ajar delay time to
elapse and if the door does not close prior to the end of this
period, the controller will activate the auxiliary relay. The auxiliary
setting defines the door-ajar time.
Auxiliary Mode 8
Auxiliary input function: Green LED control
Auxiliary output activated by: Valid user code, Auxiliary code
E.g. In auxiliary mode 8, the controller can function as a two-door
controller and also provide indicator functionality control. The
auxiliary relay is connected to the lock on the second door. The
auxiliary setting defines the door open time for the second door.
The auxiliary input is used to control the Door indicator. If the
auxiliary input is open, the indicator will flash green; if the auxiliary
input is closed, the Door indicator will flash red.
Note:
1. This mode takes control of the Door indicator LED.
2. The indicator LED will not be lit when:
3. A valid code is entered
4. While in secure mode, when waiting for secondary code.
Auxiliary Mode 9
Auxiliary input function: Red LED control
Auxiliary output activated by: Valid user code, Auxiliary code
E.g. In auxiliary mode 9, the controller can function as a two-door
controller and also provide indicator functionality control. The
auxiliary relay is connected to the lock on the second door. The
auxiliary setting defines the door open time for the second door.
The auxiliary input is used to control the indicator. If the auxiliary
input is open the Door indicator will flash red; if the auxiliary input is
closed the Door indicator will flash green.
Note:
1. This mode takes control of the Door indicator LED.
2. The indicator LED will not be lit when:
3. A valid code is entered
4. While in secure mode, when waiting for secondary code.
Page 45
AYC-Qx4 family manual