User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Installation
- 4. Wiring Instructions
- 5. Reader Functionality
- 5.1 Transmit Mode
- 5.2 Programming the AYC-E/Q/T60 Series
- 5.2.1 Entering Programming Mode
- 5.2.2 Exiting Programming Mode
- 5.2.3 Selecting Keypad Transmission Format
- 5.2.4 Keypad Transmission Format Option Number
- 5.2.4.1 Option 1: Single Key, Wiegand 6-Bit (Rosslare Format)
- 5.2.4.2 Option 2: Single Key, Wiegand 6-Bit Nibble and Parities
- 5.2.4.3 Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented
- 5.2.4.4 Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit
- 5.2.4.5 Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
- 5.2.4.6 Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit
- 5.2.4.7 Option 7: Single Key, 3x4 Matrix Keypad (MD-P64)
- 5.2.4.8 Option 8: 1 to 8 Keys BCD, Clock & Data
- 5.2.4.9 Option 9: Single Key, Wiegand 4-Bit
- 5.2.5 Selecting HID Prox Card Transmission Format
- 5.2.6 Selecting Rosslare PROX Card Transmission Format
- 5.2.7 Changing the Programming Code
- 5.2.8 Changing the Facility Code
- 5.2.9 Setting the Backlight Behavior
- 5.2.10 Setting the Reader Format
- 5.2.11 Return to Factory Default Settings
- 5.2.12 Replacing a Lost Programming Code
- 6. Controller Functionality
- 6.1 Normal, Secure, and Master Users
- 6.2 Modes of Operation
- 6.3 Changing the Modes of Operation
- 6.4 Auxiliary Input & Output
- 6.5 Door Alarms
- 6.6 Internal Case and Back Tamper
- 6.7 Lockout Feature (Keypad/Card Tamper)
- 6.8 REX Function
- 6.9 Secured Series Intelligent Power Supply
- 6.10 Programming the AYC-E/Q/T60
- 6.10.1 Entering Programming Mode
- 6.10.2 Exiting Programming Mode
- 6.10.3 Changing Lock Strike Code
- 6.10.4 Changing Auxiliary Code
- 6.10.5 Changing the Programming Code
- 6.10.6 Changing the Normal/Secure Code
- 6.10.7 Changing the Normal/Bypass Code and Door Chime Settings
- 6.10.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 6.10.9 Defining the Auxiliary Input and Output
- 6.10.10 Detailed Reference Guide
- 6.10.11 Setting the Lockout Feature
- 6.10.12 Setting the Backlight Behavior
- 6.10.13 Selecting the Rosslare PROX and HID Prox Format
- 6.10.14 Enrolling Primary and Secondary Codes
- 6.10.15 Deleting Primary and Secondary Codes
- 6.10.16 Relay Codes Assignment
- 6.10.17 PIN Code Length/Factory Default Settings
- 6.10.18 Replacing a Lost Programming Code
- 6.10.19 Replacing a Lost Normal/Secure Code
Wiring Instructions
AYC-E/Q/T60 Family Installation and Programming Manual 17
4. Wiring Instructions
The unit is supplied with a 22-inch pigtail, having a 6-conductor cable.
To connect the unit to the controller, perform the following:
Prepare the unit's cable by cutting the cable jacket back 1¼ inches
and strip the wire ½ inch.
Splice the unit’s pigtail wires to the corresponding controller wires
and cover each connection.
Refer to Table 1 and to the wiring diagrams provided on the following
pages.
Table 1: Wiring Colors
Reader Controller Color Functionality
5~16 VDC 5~16 VDC Red +DC Input
Shield/Ground Shield/Ground Black Ground
Data 1/Clock C 1 White Communication
Data 0/Data C 2 Green Communication
G.LED/LEDCTL AUX. IN Brown LED Control/Auxiliary Input
Tamper Tamper Purple Tamper
If the tamper output is used, connect the purple wire to the correct
input on the controller when used as a reader, or to a zone input of
an intruder alarm system when used as a controller.
Trim and cover all unused conductors.
• The individual wires from the unit are color-coded according the
Wiegand standard.
• When using a separate Power Supply for the Reader, this Power
Supply and that of the Controller must have a common ground.
• The Reader’s cable shield wire should preferably be attached to
an earth ground, or a signal ground connection at the panel, or
power supply end of the cable. This configuration is best for
shielding the Reader cable from external interference