When the Lock Strike is programmed for Fail Safe Operation, the door
is constantly unlocked.
6.2.3 Secure Mode
The Mode LED is red.
Only Secure and Master Users can access the premises during the
Secured mode.
A Secure User must enter their Primary and Secondary codes to gain
entry. After entering their Primary code, the Door LED flashes green
for 10 seconds, during which the Secondary code must be entered. A
Master User only needs to present the code once to gain entry.
6.3 Changing the Modes of Operation
6.3.1 Changing from Normal Mode to Secure Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Normal to Secure mode:
1. Enter the Normal/Secure code.
The Mode LED flashes red.
2. Press the “#” key to confirm the mode change.
The Mode LED turns red.