User's Manual

Table Of Contents
Controller Functionality
AYC-E/Q/T60 Family Installation and Programming Manual 67
6.10.18 Replacing a Lost Programming Code
The AYC-E/Q/T60 must be in Normal mode; otherwise, this
does not work. Make sure that the Mode LED is green before
proceeding.
1. Remove power from the Power Supply Unit.
2. Press the REX button on the Power Supply Unit.
3. Apply power to the unit with REX button pressed.
4. Release the REX button.
5. You now have 15 seconds to program a new Programming code
into the Access Control unit using the default code based on the
PIN code length you chose (see Table 4) before the controller
reverts to the existing code.
6.10.19 Replacing a Lost Normal/Secure Code
The AYC-E/Q/T60 must be in Secure mode; otherwise, this
does not work. Make sure that the Mode LED is red before
proceeding.
1. Remove power from the Power Supply Unit.
2. Press the REX button on the Power Supply Unit.
3. Apply power to the unit with the REX button pressed.
4. Release the REX button.
5. You now have 15 seconds to program a new Normal/Secure code
into the Access Control unit using the default code based on the
PIN code length you chose (see Table 4) before the controller
reverts to the existing code.