User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. Reader Operation
- 6. Proximity Operation
- 7. Keypad Operation Instructions
- 7.1 Programming Menu
- 7.2 Entering Programming Mode
- 7.3 Exiting Programming Mode
- 7.4 Selecting Keypad Transmission Format
- 7.5 Keypad Transmission Format Option Number
- 7.5.1 Option 1: Single Key, Wiegand 6-Bit (Rosslare Format)
- 7.5.2 Option 2: Single Key, Wiegand 6-Bit Nibble and Parities
- 7.5.3 Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented
- 7.5.4 Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit
- 7.5.5 Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
- 7.5.6 Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit
- 7.5.7 Option 8: 1 to 8 Keys BCD, Clock & Data
- 7.5.8 Option 9: Single Key, Wiegand 4-Bit
- 7.6 Changing the Programming Code
- 7.7 Changing the Facility Code
- 7.8 Setting the Backlight Behavior
- 7.9 Return to Factory Default Settings
- 7.10 Replacing a lost Programming Code
- 8. OSDP Operation
- A. Wiegand Output Formats
- B. Limited Warranty
Keypad Operation Instructions
AY-G/H6xx0 Installation and User Manual 19
3. Enter the appropriate option number for the keypad transmission
format that you wish to select (see Table 3).
If an incorrect option number is entered, the reader returns to
Standby mode and the keypad transmission format remains
unchanged.
The system returns to Standby mode.
You hear three beeps and the green LED blinks.
• Only one keypad transmission format can be active at any one time.
• When using the keypad transmission format "1 to 8 keys BCD,
Clock & Data" (Option 8) an additional input is required to specify
the number of keys in the PIN code.
7.5 Keypad Transmission Format Option
Number
See Table 3 to determine the Option Number for the Keypad
Transmission Format you wish to select.
Table 3: Keypad Transmission Format
Keypad Transmission Format Option Number
Single Key, Wiegand 6-Bit (Rosslare Format) 1*
Single Key, Wiegand 6-Bit with Nibble + Parity Bits 2
Single Key, Wiegand 8-Bit, Nibbles Complemented 3
4 Keys Binary + Facility code, Wiegand 26-Bit 4
1 to 5 Keys + Facility code, Wiegand 26-Bit 5
6 Keys BCD and Parity Bits, Wiegand 26-Bit 6
1 to 8 Keys BCD, Clock & Data Single Key 8
Single Key, Wiegand 4-Bit 9
Reader settings are affected by keypad programming settings.
Settings are preset by the last keypad operation.
More information on each of the different keypad transmission
formats is available in the following subsections.