User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. Reader Operation
- 6. Proximity Operation
- 7. Keypad Operation Instructions
- 7.1 Programming Menu
- 7.2 Entering Programming Mode
- 7.3 Exiting Programming Mode
- 7.4 Selecting Keypad Transmission Format
- 7.5 Keypad Transmission Format Option Number
- 7.5.1 Option 1: Single Key, Wiegand 6-Bit (Rosslare Format)
- 7.5.2 Option 2: Single Key, Wiegand 6-Bit Nibble and Parities
- 7.5.3 Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented
- 7.5.4 Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit
- 7.5.5 Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
- 7.5.6 Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit
- 7.5.7 Option 8: 1 to 8 Keys BCD, Clock & Data
- 7.5.8 Option 9: Single Key, Wiegand 4-Bit
- 7.6 Changing the Programming Code
- 7.7 Changing the Facility Code
- 7.8 Setting the Backlight Behavior
- 7.9 Return to Factory Default Settings
- 7.10 Replacing a lost Programming Code
- 8. OSDP Operation
- A. Wiegand Output Formats
- B. Limited Warranty
Keypad Operation Instructions
AY-G/H6xx0 Installation and User Manual 23
Where:
EP = Even parity for first 12 bits
OP = Odd parity for last 12 bits
A = The first key entered D = Fourth key entered
B = Second key entered E = Fifth key entered
C = Third key entered F = Sixth key entered
7.5.7 Option 8: 1 to 8 Keys BCD, Clock & Data
Option 8 buffers up to 8 keys and outputs keypad data without a
Facility code like standard Clock and Data card output.
The keypad PIN code can be one to eight digits in length. The PIN
code length is selected while programming the reader for Option 8.
The reader transmits the data when it receives the last key press of
the PIN code. The data is sent across the two data output lines as
binary data in Clock & Data format.
If * or # is pressed during PIN code entry, the keypad clears the PIN
code entry buffer, generates a beep, and is ready to receive a new
keypad PIN code.
If the entry of the keypad PIN code is disrupted and a number key or
# is not pressed within 5 seconds, the keypad clears the PIN code
entry buffer, generates a medium length beep, and is ready to receive
a new keypad PIN code.
When using the keypad transmission format "1 to 8 keys BCD,
Clock & Data" (Option 8), an additional input is required to
specify the number of keys in the PIN code.