User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. Reader Operation
- 6. Proximity Operation
- 7. Keypad Operation Instructions
- 7.1 Programming Menu
- 7.2 Entering Programming Mode
- 7.3 Exiting Programming Mode
- 7.4 Selecting Keypad Transmission Format
- 7.5 Keypad Transmission Format Option Number
- 7.5.1 Option 1: Single Key, Wiegand 6-Bit (Rosslare Format)
- 7.5.2 Option 2: Single Key, Wiegand 6-Bit Nibble and Parities
- 7.5.3 Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented
- 7.5.4 Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit
- 7.5.5 Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
- 7.5.6 Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit
- 7.5.7 Option 8: 1 to 8 Keys BCD, Clock & Data
- 7.5.8 Option 9: Single Key, Wiegand 4-Bit
- 7.6 Changing the Programming Code
- 7.7 Changing the Facility Code
- 7.8 Setting the Backlight Behavior
- 7.9 Return to Factory Default Settings
- 7.10 Replacing a lost Programming Code
- 8. OSDP Operation
- A. Wiegand Output Formats
- B. Limited Warranty
Keypad Operation Instructions
24 AY-G/H6xx0 Installation and User Manual
7.5.8 Option 9: Single Key, Wiegand 4-Bit
With this option, each key press immediately sends 4 bits of data,
with no parity bits added.
0 = 0000 6 = 0110
1 = 0001 7 = 0111
2 = 0010 8 = 1000
3 = 0011 9 = 1001
4 = 0100 *= 1010 ="A" in Hexadecimal
5 = 0101 #=1011 ="B" in Hexadecimal
7.6 Changing the Programming Code
To change the Programming code:
1. Enter Programming mode.
2. Press 3 to enter Menu 3.
The green LED blinks.
3. Enter the new 4-digit code you wish to set as the Programming
code.
The system returns to Standby mode.
You hear three beeps and the green LED blinks.
• The Programming code cannot be erased; the code 0000 is invalid
and does not erase the Programming code.
•
The factory default 4-digit Programming code is 1234.
7.7 Changing the Facility Code
To change the Facility code:
1. Enter Programming mode.
2. Press 4 to enter Menu 4.
The green LED blinks.
3. Enter the new 3-digit code you wish to set as the Facility code.