Technical Specs

Electrical Characteristics
LED/Buzzer Controls Dry Contact, N.O.
Tamper Output
Open collector, active low, max. sink current 20 mA @12 VDC, 10 mA@5VDC. Current
limit: 500Ω series resistance
Maximum Cable Distance to
Controller
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1,200 m (4,000 ft) with 2x2 18 AWG twisted shielded cable
Environmental Characteristics
Operating Temp. Range -35°C to 66°C (-31°F to 150°F)
Operating Humidity Range 0 to 95% (non-condensing)
Operating Environment
Weather-resistant, UV-resistant, meets
IP65
, epoxy-potted, suitable for indoor and
outdoor use
Vandal Resistance
IK?
Physical Characteristics
Dimensions
(H x W x D)
Weight
*Read range listed is statistical mean rounded to nearest centimeter, measured in open air using Rosslare MIFARE Classic EV1 (ISO card). Form factor, technology and
environmental conditions, including metallic mounting surface, can degrade read range performance; plastic spacers are recommended to improve performance on metallic
mounting surfaces.
3. Installation
3.1. Mounting the Multi-Smart R eaders
When selecting an area for mounting, ensure the location is flat.
To Mount Multi-Smart Readers:
1. Drill 2 holes in the wall, using the mounting template provided in the installation.
2. Insert 2 anchors provided into the drilled holes.
3. Mount the bracket on the wall using the 2 screws provided.
Multi-Smart™ Readers Installation & User Guide
www.rosslaresecurity.com
2
88 x 48 x 24 mm (3.5 x 1.9 x 0.9 in.)
190 g (6.7 oz)