User's Manual
Table Of Contents
- 1.2.3.1. Cable & Connector
- 1.2.3.2. Pin Details
- 1.2.3.3. Terminal <- > MCP040 wiring
- 1.2.3.4. Terminal <- > LC015B wiring
- 1.2.3.5. Terminal <- > EM Type Door Lock wiring
- 1.2.3.6. Terminal <- > WIEGAND Device wiring
- 3.1.6.1. Single Type (Door Lock=STRIKE)
- 3.1.6.2. Single Type (Door Lock=MOTOR)
- 3.1.6.3. Single Type (Lock Controller=LC010)
- 3.1.6.4. Single Type (Lock Controller=LC015)
- 3.1.6.5. Dummy Type (RS485=MCP040)
- 3.1.6.6. Network Type (Door Lock=STRIKE)
- 3.1.6.7. Network Type (Door Lock=MOTOR)
- 3.1.6.8. Network Type (Lock Controller=LC010)
- 3.1.6.9. Network Type (Lock Controller=LC015)
- 3.4.1.1. USER TYPE
- 3.4.1.2. AUTH TYPE
- 3.4.1.3. INPUT FP
- 3.4.1.4. INPUT CARD
- 3.4.2.1. AUTO ADD – 1. FP
- 3.4.2.2. AUTO ADD
- 3.6.1.1. TYPE
- 3.6.1.2. AUTO TNA
- 3.6.2.1. Language
- 3.6.2.2. SHOW ID
- 3.6.2.3. USER LOGO
- 3.6.2.4. USER ID LEN
- 3.6.2.5. DATE
- 3.6.3.1. LOG SAVE
- 3.6.3.2. IMAGE SAVE
- 3.6.4.1. RESULT
- 3.6.4.2. NET ERROR
- 3.6.4.3. PING
- 3.7.1.1. 1:1 LEVEL
- 3.7.1.2. 1: N LEVEL
- 3.7.1.3. LFD LEVEL
- 3.7.1.4. AUTH TIME
- 3.8.1.1. LOCK1 type
- 3.8.1.2. LOCK1 OPEN TIME
- 3.8.1.3. LOCK2 type
- 3.8.1.4. LOCK2 OPEN TIME
- 3.8.1.5. OPEN ALARM
- 3.8.1.6. DM0
- 3.8.1.7. DM1
- 3.8.1.8. DM2
- 3.8.2.1. TYPE
- 3.8.2.2. DEV ID
- 3.8.3.1. WIRE-INPUT
- 3.8.3.2. WIRE-OUTPUT
- 3.8.3.3. CUSTOM BIT LENGTH
- 3.8.3.4. SITE CODE
- 3.8.3.5. SEND INFO
- 3.10.1.1. CONFIG
- 3.10.1.2. LOG DB INIT
- 3.10.1.3. FACTORY INIT
- 3.10.2.1. INT DEVICE
- 3.10.2.2. EXT DEVICE
- 3.10.3.1. LOG EXPORT
- 3.10.3.2. USER EXPORT
- 3.10.3.3. USER INPUT
- 3.10.3.4. FW UPDATE
AY-B9250BT User Guide 33
ADMIN Available to add and delete user.
Available to access menu and modify it.
When selecting the administrator, the screen is displayed as follows.
AUTH TYPE 3.4.1.2.
There are FP (Fingerprint), Card, and MCARD (Mobile card) in the menu.
But MCARD can only provide the check state, and do not provide checking or unchecking. For
checking or unchecking with MCARD, it is only available via Server and Admin App.
There are AND and OR in authentication conditions.
In AND, all authentication conditions should be satisfactory and then authentication succeeds.
In OR, one of authentication conditions should be satisfactory and authentication succeeds.
FP:0 ➔ FP is abbreviation of Finger Print.
0 means the registered FP number. (1FP means 2 fingerprints)
CD:0➔ CD is abbreviation of CARD.
0 means the registered CARD number.
Maximum card number is 1.
(U) ➔ Means your Registration Authority is general user (USER).
(A) ➔ Means your Registration Authority is administrator (ADMIN).
[FR Authentication] [Card Authentication] [FP or Card
Authentication]
[FP and Card
Authentication]
INPUT FP 3.4.1.3.
Input the same fingerprint twice when you check the Fingerprint as authentication type. If
you want to add only one fingerprint, select 1. NO. If you input the fingerprint second times
and they are normal, INPUT OK is displayed. If you want to add more fingerprints, select 2.
YES. One user can register 20 people for maximum.