AY-B9350 User Manual 49
and monitoring pin of the Lock must be also connected to M0. In addition, M0 must be
set to [door open status NO] or [door open status NC] as well.
▶ Tamper Alarm
If this is checked (
), warning sound will be made when the terminal is disassembled.
To apply the setting value, press [OK] button, or press [BACK] button to cancel and to
move to the upper menu.
3.7.4. Lock Setting
Select [Terminal]
[Lock] in the main menu to display the screen below.
▶
Default setting: same with the setting in the left
screen
▶ Lock 1 option
- Not use: when it is not used
- Strike/Auto/successful authentication notice: warning lamp to indicate Strike type,
auto door or authentication success/failure is connected to Lock1
- Motor lock 1: when a motor lock is connected
▶ Lock 2 option
- Not use: when it is not used
- Authentication failure notice: warning lamp to indicate authentication failure is
connected to Lock2
- Motor lock 2: when a motor lock is connected
▶ Lock 1 Duration (ms)
This is to designate time to give signal when Lock 1 is set to ‘Strike/Auto/successful
authentication notice’. Since it is set to ms unit, set it to 3000 to designate it to 3
seconds. Strike type means time until the door is closed again when the door is open
after authentication.
▶ Lock 2 Duration (ms)
This is to designate time to give signal when Lock 2 is set to ‘authentication failure
notice’. Since it is set to ms unit, set it to 3000 to designate it to 3 seconds.