MD-W11 Installation Manual Page 19
Set the unit channels with Dipswitches 5 and 6.
Dipswitch
5
Dipswitch
6
Channel
H Model
Channel
G Model
ON
ON
869.50 Mhz
433.60 Mhz
ON
OFF
868.45 Mhz
433.40 Mhz
OFF
ON
868.30 Mhz
433.20 Mhz
OFF
OFF
868.15 Mhz
433.00 MHz
Note:
Dipswitches 5 and 6 must be synchronized in the Far and
Near Units.
Choose the same channel for both units.
If the LED’s flash, the dipswitches have not been set properly. In
that case, first re-set the dipswitches, and then power the unit off
and on.
During enrollment, the enrolling LED blinks first, followed by the TX
LED, which blinks when it is transmitting. The enrolling process is
finished when the enrolling LED shines steadily.
After enrolling, return dipswitch 7 to ON (normal mode).
Note: