User Manual

Table Of Contents
Enrollment
MD-W11 Installation Manual Page 20
4.2.1. Near and Far Unit Modes
The current unit mode is indicated by a steady or blinking LED.
The three modes (Normal, Enrolling, and Trouble) of the NEAR and
FAR units are described in detail below.
The normal mode is “idle, and the LEDs behave as follows:
Normal Mode:
PWR - Power ON - steady
Tx - Sending transmission - blinking when sending
Rx - Receiving transmission - blinking when receiving
SYS - System OK blinking
Note:
If SYS LED is not blinking, it indicates a serious error.
A blinking TRBL indicates that there is trouble. Refer to the Trouble
Mode for a list of possible problems.
The following steps indicate how to set the Enrolling mode (for
retention of transmitted data).
Enrolling Mode:
1. Set Dipswitch 7 on both units (Near and Far) to OFF.
2. Power up both units.
3. PWR IS steady and ENRL IS blinking.
4. The Far unit sends its ID to the Near unit.
5. The Near unit receives an ID and sends it to the Far unit
6. The Far unit receives the Near unit’s ID and ENRL is steady.