User Manual

Table Of Contents
Enrollment
MD-W11 Installation Manual Page 21
The MD-W11
Trouble Mode:
FAR module
Reader tamper
detects the following troubles:
FAR module tamper
Low battery
AC Fail
RF device Failure / Problem
Incorrect dipswitch setting
Following detection of any of the said problems or failures, the
FAR module behaves as shown in the following table:
Problem
Activity
Reader tamper
Sends trouble and problem to the
Near
module.
FAR module tamper
Sends trouble and problem to the
Near
module.
Low battery
Sends trouble and problem to the Near
module.
Trouble LED turns on.
AC Fail
Sends trouble and problem to the Near
module.
Trouble LED turns on.
RF device Failure /
Problem
Trouble LED flashes at a fast rate. (after
power on)
Incorrect dipswitch
setting
All LEDs flash at a slow rate. (after
power on)