Programming
AC-F/G4x Series Installation and Programming Manual 41
For example, 0312 means a Fail Secure Operation consisting
of a 3-minute siren and a 12-
second Lock Strike release time.
You hear three beeps.
The system returns to Normal mode.
5.9
Setting Auxiliary Modes
The default auxiliary setting is 2004.
Auxiliary Relay activation is subject to
the user’s Auxiliary
code assignment (excluding Shunt, which is activated by
all users). For more
details, see Section 5.14.
To set Auxiliary modes:
1.
Enter Programming mode.
2.
Press 6 to enter Menu 6.
The left LED flashes green.
Green
Green
Green
Green