Programming Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Installation
- 4. Operation
- 5. Programming
- 5.1 Entering the Programming Mode
- 5.2 Exiting the Programming Mode
- 5.3 Changing the Open Code
- 5.4 Changing the Auxiliary Code
- 5.5 Changing the Programming Code
- 5.6 Changing the Normal/Secure Code
- 5.7 Changing the Normal/Bypass Code
- 5.8 Setting Fail Safe/Secure Operation
- 5.9 Setting Auxiliary Modes
- 5.10 Setting the Lockout Feature
- 5.11 Setting the Backlight Behavior
- 5.12 Enrolling Primary and Secondary Codes
- 5.13 Deleting Primary and Secondary Codes
- 5.14 Relay Codes Assignment
- 5.15 Changing PIN Code Length/Factory Default Settings
- 5.16 Replacing a Programming Code
- 5.17 Replacing a Normal/Secure Code
- A. Declaration of Conformity
- B. Limited Warranty
Technical Specifications
14 AC-F/G4x Series Installation and Programming Manual
2. Technical Specifications
AC-F43
AC-F44
AC-G43
AC-G44
Input
Voltage
VDC 12 to 24 VDC
VAC 16 to 24 VAC
Maximum Input Current
(12 VDC)
125 mA 160 mA 125 mA 160 mA
Standby Input Current
(12 VDC)
75 mA 95 mA 75 mA 95 mA
Maximum Relay Current 2 A
REX Input Normally Open (dry contact)
Aux. Input Normally Open (dry contact)
Max. Proximity Read
Range*
N/A 75 mm
(3.0 in.)
N/A 80 mm
(3.2 in.)
Proximity Modulation N/A
ASK at 125
kHz
N/A
ASK at 125
kHz
Proximity Card
Compatibility
N/A
26 Bits EM
cards
N/A
26 Bits EM
cards
LED Indicators Two 3-colored LED (Mode and Door)
Operating Temp. Range -30°C to 65°C (-22°F to 150°F)
Operating Humidity
Range
0 to 95% (non-condensing)
Outdoor Usage Weather resistant, meets IP65, epoxy-potted