AC-F/G4x Series Installation and Programming Manual 49
on the door. The auxiliary relay is to be wired to the alarm
system. If the door is opened, the controller waits for the Door
Ajar Delay time to elapse and if the door does not close prior to
the end of this period, the controller activates the auxiliary relay.
The auxiliary setting defines the Door Ajar time.
If the BL-D40 external sounder is connected in the system and a
door-ajar event occurs, the BL-D40 chimes every few seconds for
1 minute or until the door is closed.
5.9.9 Auxiliary Mode 8
This mode control
s the door indicator (right LED).
The
right LED is not lit when:
A valid code is entered
While in Secure mode when waiting for Secondary code.
Auxiliary input function: Green LED control
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 8, the controller can function as a
2-door controller and also provide LED indicator functionality
control. The auxiliary relay is connected to the lock on the
second door. The auxiliary setting defines the Door Open time
for the second door. The auxiliary input is used to control the
door indicator (right LED). If the auxiliary input is open, the right
LED flashes green; if the auxiliary input is closed, the right LED
flashes red.