Programming Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Installation
- 4. Operation
- 5. Programming
- 5.1 Entering the Programming Mode
- 5.2 Exiting the Programming Mode
- 5.3 Changing the Open Code
- 5.4 Changing the Auxiliary Code
- 5.5 Changing the Programming Code
- 5.6 Changing the Normal/Secure Code
- 5.7 Changing the Normal/Bypass Code
- 5.8 Setting Fail Safe/Secure Operation
- 5.9 Setting Auxiliary Modes
- 5.10 Setting the Lockout Feature
- 5.11 Setting the Backlight Behavior
- 5.12 Enrolling Primary and Secondary Codes
- 5.13 Deleting Primary and Secondary Codes
- 5.14 Relay Codes Assignment
- 5.15 Changing PIN Code Length/Factory Default Settings
- 5.16 Replacing a Programming Code
- 5.17 Replacing a Normal/Secure Code
- A. Declaration of Conformity
- B. Limited Warranty
Programming
AC-F/G4x Series Installation and Programming Manual 51
red, and the controller beeps every two seconds. The default
setting for the Lockout Feature is 4000 (Lockout Disabled).
Using the lockout feature is highly recommended, especially
when selecting to use short PIN code l
ength (4 or 5 digits).
To define the Lockout feature:
1.
Enter Programming mode.
2.
Press 6 to enter Menu 6.
The left LED flashes green.
3.
Construct a code using the following
instructions:
Second digit
Set the number of wrong code attempts, which causes a
Lockout between 0 and 9 attempts.
Third and fourth digits
Sets the Duration of the lockout, betwee
n 00 and 99; the
value is multiplied by ten, resulting in 0 to 990 seconds.
Green
Green
Green