Programming Manual
Table Of Contents
- 1. Introduction
- 2. Installation
- 3. Operation
- 4. Programming
- 4.1 Entering the Programming Mode
- 4.2 Exiting the Programming Mode
- 4.3 Changing the Open Code
- 4.4 Changing the Auxiliary Code
- 4.5 Changing the Programming Code
- 4.6 Changing the Normal/Secure Code
- 4.7 Changing the Normal/Bypass Code
- 4.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 4.9 Setting Auxiliary Modes
- 4.10 Keypad Heater Operation
- 4.11 Setting the Lockout Feature
- 4.12 Setting the Backlight Behavior
- 4.13 Enrolling Primary and Secondary Codes
- 4.14 Deleting Primary and Secondary Codes
- 4.15 Relay Codes Assignment
- 4.16 Changing PIN Code Length/Factory Default Settings
- 4.17 Replacing a Programming Code
- 4.18 Replacing a Normal/Secure Code
- 5. Technical Specifications
Programming
40 AC-Q4x Series Installation and Programming Manual
If the BL-D40 External Sounder is connected in the system and a
door-ajar event occurs, the BL-D40 chimes every few seconds for 1
minute or until the door is closed.
4.9.9 Auxiliary Mode 8
Auxiliary input function: Green LED control
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 8, the controller can function as a
2-door controller and also provide indicator functionality control.
The auxiliary relay is connected to the lock on the second door. The
auxiliary setting defines the Door Open time for the second door.
The auxiliary input is used to control the Door indicator. If the
auxiliary input is open, the indicator flashes green; if the auxiliary
input is closed, the Door indicator flashes red.
This mode takes control of the Door indicator LED.
The indicator LED is not lit when:
• A valid code is entered
•
While in Secure mode, when waiting for a secondary code
4.9.10 Auxiliary Mode 9
Auxiliary input function: Red LED control
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 9, the controller can function as a
2-door controller and also provide indicator functionality control.
The auxiliary relay is connected to the lock on the second door. The
auxiliary setting defines the Door Open time for the second door.
The auxiliary input is used to control the indicator. If the auxiliary
input is open, the Door indicator flashes red; if the auxiliary input is
closed, the Door indicator flashes green.
This mode takes control of the Door indicator LED.
The indicator LED is not lit when:
• A valid code is entered
• While in Secure mode, when waiting for a secondary code