Programming Manual

Table Of Contents
Programming
42 AC-Q4x Series Installation and Programming Manual
the controller beeps every two seconds. The default setting for the
Lockout Feature is 4000 (Lockout Disabled).
Using the lockout feature is highly recommended, especially
when selecting to use short PIN code length (4 or 5 digits).
To define the Lockout feature:
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The Mode indicator flashes green.
3. Construct a code using the following
instructions:
Second digit
Set the number of wrong code attempts, which causes a
Lockout between 0 and 9 attempts.
Third and fourth digits
Sets the Duration of the lockout, between 00 and 99; the
value is multiplied by ten, resulting in 0 to 990 seconds.
Mode
Door
Green
Mode
Door
Green
Green