Programming Manual
Table Of Contents
- 1. Introduction
- 2. Installation
- 3. Operation
- 4. Programming
- 4.1 Entering the Programming Mode
- 4.2 Exiting the Programming Mode
- 4.3 Changing the Open Code
- 4.4 Changing the Auxiliary Code
- 4.5 Changing the Programming Code
- 4.6 Changing the Normal/Secure Code
- 4.7 Changing the Normal/Bypass Code
- 4.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 4.9 Setting Auxiliary Modes
- 4.10 Keypad Heater Operation
- 4.11 Setting the Lockout Feature
- 4.12 Setting the Backlight Behavior
- 4.13 Enrolling Primary and Secondary Codes
- 4.14 Deleting Primary and Secondary Codes
- 4.15 Relay Codes Assignment
- 4.16 Changing PIN Code Length/Factory Default Settings
- 4.17 Replacing a Programming Code
- 4.18 Replacing a Normal/Secure Code
- 5. Technical Specifications
Programming
AC-Q4x Series Installation and Programming Manual 53
4.17 Replacing a Programming Code
The controller must be in Normal mode for the procedure to
work. Ensure that the Mode indicator is green before
proceeding.
To replace a Programming code:
1. Remove power from the controller.
2. Press and hold the REX button.
3. Apply power to the unit with the REX button pressed.
4. Release the REX button.
5. You now have 15 seconds to program a new programming
code into the unit using the initial default code before the
controller reverts to the existing code.
4.18 Replacing a Normal/Secure Code
The controller must be in its Secure mode for the procedure
to work. Ensure that the Mode indicator is red before
proceeding.
To replace a Normal/Secure code:
1. Remove power from the controller.
2. Press and hold the REX button.
3. Apply power to the unit with the REX button pressed.
4. Release the REX button.
5. You now have 15 seconds to use the Normal/Secure code to
return to the Normal mode.
6. Once in Normal mode, enter Programming mode to program a
new Normal/Secure code.