Programming Manual
Table Of Contents
- 3.2.3.1 Keypad Transmission Formats
- 3.2.4.1 Proximity Card Transmission Formats
- 4.2.4.1 Changing from Normal Mode to Secure Mode
- 4.2.4.2 Changing from Secure Mode to Normal Mode
- 4.2.4.3 Changing from Normal Mode to Bypass Mode
- 4.2.4.4 Changing from Bypass Mode to Normal Mode
- 4.9.9.1 Auxiliary Mode 0
- 4.9.9.2 Auxiliary Mode 1
- 4.9.9.3 Auxiliary Mode 2
- 4.9.9.4 Auxiliary Mode 3
- 4.9.9.5 Auxiliary Mode 4
- 4.9.9.6 Auxiliary Mode 5
- 4.9.9.7 Auxiliary Mode 6
- 4.9.9.8 Auxiliary Mode 7
- 4.9.9.9 Auxiliary Mode 8
- 4.9.9.10 Auxiliary Mode 9
- 4.9.12.1 Primary Codes
- 4.9.12.2 Secondary Codes
- 4.9.12.3 Enrolling Methods
- 4.9.12.4 Enrolling Primary and Secondary Codes using Standard Method
- 4.9.12.5 Enrolling Secondary Codes using Search Method
- 4.9.13.1 Deleting Primary and Secondary Codes using Standard Method
- 4.9.13.2 Deleting Primary and Secondary Codes using Search Method
- 4.9.14.1 Relay Code Assignment using Standard Method
- 4.9.14.2 Relay Code Assignment using Search Method
Installation
12 AYC-Ex5/T65 Series Installation and Programming Manual
3. Insert the wall plugs into both mounting holes.
4. Drill a 10-mm (7/16”) hole for the cable. If the surface is metal,
place a grommet or electrical tape around the edge of the hole.
5. Insert the unit’s cable wire into the cable hole and wire the unit
as described in Section 2.2.
6. Using the two mounting screws, screw the unit to the wall
through the two wall plugs.
The unit can also be mounted using strong epoxy glue. After
application, firmly hold the unit in place until the glue dries.
2.2 Wiring
The unit is supplied with a 6-conductor 150-cm (60-in.) pigtail with
exposed wires coated with solder.
2.2.1 Wiring the Unit as a Reader
If you connect the unit to a standard access control unit, it
automatically functions as a reader.
To connect the unit as a reader (to a controller):
1. Select the appropriate connections according to Table 1.
Table 1: Wiring the Reader to the Controller
Wire Color Function
Black/Shield Ground (+)
Red Vin (-)
Green Data 0/Data (D0)
White Data 1/Clock (D1)
Brown LED control
Purple Tamper
2. Prepare the controller cable by cutting the cable jacket back 3.2
cm (1¼”) and strip the wire 1.3 cm (½”).