Programming Manual
Table Of Contents
- 3.2.3.1 Keypad Transmission Formats
- 3.2.4.1 Proximity Card Transmission Formats
- 4.2.4.1 Changing from Normal Mode to Secure Mode
- 4.2.4.2 Changing from Secure Mode to Normal Mode
- 4.2.4.3 Changing from Normal Mode to Bypass Mode
- 4.2.4.4 Changing from Bypass Mode to Normal Mode
- 4.9.9.1 Auxiliary Mode 0
- 4.9.9.2 Auxiliary Mode 1
- 4.9.9.3 Auxiliary Mode 2
- 4.9.9.4 Auxiliary Mode 3
- 4.9.9.5 Auxiliary Mode 4
- 4.9.9.6 Auxiliary Mode 5
- 4.9.9.7 Auxiliary Mode 6
- 4.9.9.8 Auxiliary Mode 7
- 4.9.9.9 Auxiliary Mode 8
- 4.9.9.10 Auxiliary Mode 9
- 4.9.12.1 Primary Codes
- 4.9.12.2 Secondary Codes
- 4.9.12.3 Enrolling Methods
- 4.9.12.4 Enrolling Primary and Secondary Codes using Standard Method
- 4.9.12.5 Enrolling Secondary Codes using Search Method
- 4.9.13.1 Deleting Primary and Secondary Codes using Standard Method
- 4.9.13.2 Deleting Primary and Secondary Codes using Search Method
- 4.9.14.1 Relay Code Assignment using Standard Method
- 4.9.14.2 Relay Code Assignment using Search Method
Installation
AYC-Ex5/T65 Series Installation and Programming Manual 13
3. Splice the reader’s pigtail wires to the corresponding controller
wires and cover each joint with insulating tape.
4. If the tamper output is being utilized, connect the purple wire to
the correct input on the controller.
5. Trim and cover all conductors that are not used.
• The individual wires extending from the reader are color-coded
according to the required Wiegand standard.
• When using a separate power supply for the reader, this supply and
the controller’s power supply must have a common ground. A linear
power supply is recommended.
• Attach the cable shield wire on the reader to an earth ground (best),
or to a signal ground connection at the panel or power supply end
of the cable. This configuration is best for shielding the reader
cable from external interference.
2.2.2 Wiring the Unit as a Controller
If you connect the unit to a Rosslare secured power supply, it
automatically functions as a controller.
To connect the unit as a controller:
1. Select the appropriate connections according to Table 2.
Table 2: Wiring the Unit as a Controller
Controller Wire Color Function Note
- Red +DC Input Wired to the PS-x25x
+ Black Ground Wired to the PS-x25x
C 1 White Communication Wired to the PS-x25x
C 2 Green Communication Wired to the PS-x25x
AUX. IN Brown Auxiliary Input Wired to input
N/A
Purple Not in use N/A