Programming Manual
Table Of Contents
- 3.2.3.1 Keypad Transmission Formats
- 3.2.4.1 Proximity Card Transmission Formats
- 4.2.4.1 Changing from Normal Mode to Secure Mode
- 4.2.4.2 Changing from Secure Mode to Normal Mode
- 4.2.4.3 Changing from Normal Mode to Bypass Mode
- 4.2.4.4 Changing from Bypass Mode to Normal Mode
- 4.9.9.1 Auxiliary Mode 0
- 4.9.9.2 Auxiliary Mode 1
- 4.9.9.3 Auxiliary Mode 2
- 4.9.9.4 Auxiliary Mode 3
- 4.9.9.5 Auxiliary Mode 4
- 4.9.9.6 Auxiliary Mode 5
- 4.9.9.7 Auxiliary Mode 6
- 4.9.9.8 Auxiliary Mode 7
- 4.9.9.9 Auxiliary Mode 8
- 4.9.9.10 Auxiliary Mode 9
- 4.9.12.1 Primary Codes
- 4.9.12.2 Secondary Codes
- 4.9.12.3 Enrolling Methods
- 4.9.12.4 Enrolling Primary and Secondary Codes using Standard Method
- 4.9.12.5 Enrolling Secondary Codes using Search Method
- 4.9.13.1 Deleting Primary and Secondary Codes using Standard Method
- 4.9.13.2 Deleting Primary and Secondary Codes using Search Method
- 4.9.14.1 Relay Code Assignment using Standard Method
- 4.9.14.2 Relay Code Assignment using Search Method
Reader Operation
AYC-Ex5/T65 Series Installation and Programming Manual 27
3.2.6 Changing the Facility Code
To change the Facility code:
• The Facility code can be in the range of 000 to 255.
• The default Facility code is 0.
1. Enter Programming mode.
2. Press 4 to enter Menu 4.
The left LED turns red.
3. Enter the new 3-digit Facility code.
You hear three beeps.
The system returns to Standby mode.
3.2.7 Setting the Backlight Behavior
To set the backlight behavior:
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The left LED turns red.
3. Enter one of the following codes:
0 for always off
1 for always on
2 for 10 sec. backlight after a key is pressed otherwise off
(Transmit LED also off)
3 for 10 sec. backlight after a key is pressed otherwise dimmed
Green
Red
Green
Red
Green
Red
Green