Reader Operation
AYC-Ex5/T65 Series Installation and Programming Manual 29
3.2.9 Replacing a Lost Programming Code
In the event that the Programming code is forgotten, the unit can be
reprogrammed in the field.
To replace a lost Programming code:
1. Remove power from the reader.
2. Activate tamper by removing the reader from the wall or
removing the reader's case.
3. Apply power to the reader.
4. You now have 10 seconds to enter Programming mode using
the factory default Programming code 1234.