Programming Manual
Table Of Contents
- 3.2.3.1 Keypad Transmission Formats
- 3.2.4.1 Proximity Card Transmission Formats
- 4.2.4.1 Changing from Normal Mode to Secure Mode
- 4.2.4.2 Changing from Secure Mode to Normal Mode
- 4.2.4.3 Changing from Normal Mode to Bypass Mode
- 4.2.4.4 Changing from Bypass Mode to Normal Mode
- 4.9.9.1 Auxiliary Mode 0
- 4.9.9.2 Auxiliary Mode 1
- 4.9.9.3 Auxiliary Mode 2
- 4.9.9.4 Auxiliary Mode 3
- 4.9.9.5 Auxiliary Mode 4
- 4.9.9.6 Auxiliary Mode 5
- 4.9.9.7 Auxiliary Mode 6
- 4.9.9.8 Auxiliary Mode 7
- 4.9.9.9 Auxiliary Mode 8
- 4.9.9.10 Auxiliary Mode 9
- 4.9.12.1 Primary Codes
- 4.9.12.2 Secondary Codes
- 4.9.12.3 Enrolling Methods
- 4.9.12.4 Enrolling Primary and Secondary Codes using Standard Method
- 4.9.12.5 Enrolling Secondary Codes using Search Method
- 4.9.13.1 Deleting Primary and Secondary Codes using Standard Method
- 4.9.13.2 Deleting Primary and Secondary Codes using Search Method
- 4.9.14.1 Relay Code Assignment using Standard Method
- 4.9.14.2 Relay Code Assignment using Search Method
Controller Operation
AYC-Ex5/T65 Series Installation and Programming Manual 49
3. Construct a code using the following
instructions:
Second digit
Set the number of wrong code attempts, which causes a
Lockout between 0 and 9 attempts.
Third and fourth digits
Sets the Duration of the lockout, between 00 and 99; the
value is multiplied by ten, resulting in 0 to 990 seconds.
4.9.11 Setting the Backlight Behavior
The controller allows you to define the way the unit’s backlight
works.
To set the backlight behavior:
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The left LED flashes green.
3. Enter one of the following codes:
5000 – Backlight off
5100 – Backlight on (default)
5200 – Backlight is off, activates for 10 seconds when a key is
pressed, after which it dims until off
5300 – Backlight is dimmed, activates for 10 seconds when a
key is pressed, after which it returns to a dimmed level
Green
Green