Programming Manual

Technical Specifications
AYC-Ex5/T65 Series Installation and Programming Manual 61
5. Technical Specifications
Specification AYC-E55 AYC-E65B,
AYC-E65BB
AYC-T65
Electrical Characteristics
Power Supply Type Linear type (recommended)
Operating Voltage
Range
5–16 VDC (when used as a controller, provided by the
secured intelligent power supply)
Input Current
Standby
15 m A@12 VDC 92 mA @12 VDC
Max Input Current 40 mA @16 VDC 105 mA @16 VDC
LED Control Input Dry contact N.O.
Tamper Output Open collector, active low, 30 mA max sink current
Cable Distance to
Host Controller
Up to 500 ft. (150 meters) using an 18 AWG cable
Max. Proximity Card
Read Range*
N/A 40 mm (1.6 in.)
Proximity Card
Modulation
N/A ASK at 125 kHz
Proximity Card
Compatibility
N/A EM cards
Card Transmit
Format (Reader)
N/A Wiegand 26-Bit, or Clock & Data
Keypad Transmit
Format (Reader)
Programmable PIN code formats
LED Indicators Two tri-colored LEDs
Communication Data1/C1, Data0/C2open collector, 5 V
termination
* Measured using a Rosslare proximity card or equivalent. Range also
depends on electrical environment and proximity to metal.