Programming Manual
Table Of Contents
- 3.2.3.1 Keypad Transmission Formats
- 3.2.4.1 Proximity Card Transmission Formats
- 4.2.4.1 Changing from Normal Mode to Secure Mode
- 4.2.4.2 Changing from Secure Mode to Normal Mode
- 4.2.4.3 Changing from Normal Mode to Bypass Mode
- 4.2.4.4 Changing from Bypass Mode to Normal Mode
- 4.9.9.1 Auxiliary Mode 0
- 4.9.9.2 Auxiliary Mode 1
- 4.9.9.3 Auxiliary Mode 2
- 4.9.9.4 Auxiliary Mode 3
- 4.9.9.5 Auxiliary Mode 4
- 4.9.9.6 Auxiliary Mode 5
- 4.9.9.7 Auxiliary Mode 6
- 4.9.9.8 Auxiliary Mode 7
- 4.9.9.9 Auxiliary Mode 8
- 4.9.9.10 Auxiliary Mode 9
- 4.9.12.1 Primary Codes
- 4.9.12.2 Secondary Codes
- 4.9.12.3 Enrolling Methods
- 4.9.12.4 Enrolling Primary and Secondary Codes using Standard Method
- 4.9.12.5 Enrolling Secondary Codes using Search Method
- 4.9.13.1 Deleting Primary and Secondary Codes using Standard Method
- 4.9.13.2 Deleting Primary and Secondary Codes using Search Method
- 4.9.14.1 Relay Code Assignment using Standard Method
- 4.9.14.2 Relay Code Assignment using Search Method
Reader Operation
18 AYC-Ex5/T65 Series Installation and Programming Manual
3.2.1 Entering Programming Mode
To reach the Programming Menu System, the unit must first be
placed into Programming mode.
• The factory 4-digit Programming code is 1234.
• If a Programming code is not entered within 30 seconds, the unit
returns to Standby mode.
To enter Programming mode:
1. Press # four times.
The left LED turns off and the right LED turns
red.
2. Enter your 4-digit Programming code.
If the Programming code is valid, the right
LED turns green.
If the Programming code is invalid, you hear a long beep and
the reader returns to Standby mode.
If no key is pressed for 30 seconds while in Programming
mode, the unit returns to Standby mode
3.2.2 Exiting Programming Mode
To exit Programming mode:
1. Press # to exit Programming mode at any time.
You hear a beep.
The left LED turns red and the right LED turns
off.
This indicates that the unit has returned to Standby mode.
Red
Green
Red