Specifications
Installer Menu 
32  HLX-40 Installer Manual 
Browse the desired devices listed below to be enrolled using the Menu button 
and access it by pressing the Enter button: 
  Detectors 
  Remote controls 
  RF Sirens 
  Keypads 
  Repeaters 
6.4.1  Detectors 
You can enroll up to 39 detectors, one detector per zone, numbered 01 
through 39. Zone no. 40, which is dedicated to a hardwire detector, can only 
be enabled or disabled under this submenu. By default, this zone is disabled. 
To enroll/delete a detector: 
1.  Select the desired zone by either browsing all 39 zones using the Menu 
button or by entering the zone number using the numeric keypad. 
2.  Select enrollment method, either Normal or Tamper. 
  If no detector is associated to the selected zone, the screen shows a 
message saying “waiting for detector signal” for 30 seconds. 
  When browsing the zones, each zone already enrolled indicates "RF 
ID code". 
3.  Press Enter to delete the detector (or ESC to go back). 
4.  Initiate a transmission from the detector. 
  In Normal enrollment any transmission is accepted (Alarm, Tamper, 
or any other transmission available, see the detector’s manual for 
reference). 
  In Tamper enrollment, only Tamper activation is accepted all other 
signals are ignored. 
Tamper enrollment is suitable for areas with multiple sensors thus preventing 
false enrollment. 
5.  When the transmission is detected, you are asked to press the Enter 
button to store the detector into the zone. 
When enrolling smoke and heat detectors, make sure to select the zone type 
“fire”. 
If no signal is received with the allocated 30 seconds, the unit returns to 
Normal mode. 