Specifications
Installer Menu 
48  HLX-40 Installer Manual 
i. 
CS Primary
 – Using the Menu button, select either PSTN or GSM 
communication types. Press Enter to confirm. 
ii. 
CS Secondary
 – Using the Menu button, select either PSTN or 
GSM communication types. Press Enter to confirm. 
If the GSM stick is not installed, the Link Type is set to PSTN, and cannot be 
changed. 
6.6.5  Line Test 
Enables you to specify the time when the phone line and CS reporting are 
tested and reported to the central station, as well as the time interval between 
each test (periodic reporting). 
To set up line test: 
1.  Using the Menu button, select one of the two options to define, and 
press Enter to confirm: 
  Repeats – Specify the number of days between tests. Using the 
numeric keypad, choose 1 to 30 days press Enter to save; default is 
7. 
  Test_Time – Specify the hour of the day to perform the line test. 
Using the numeric keypad, type the four digits of the desired hour 
(24H convention), press Enter to save. The test time is set at 12:00 by 
default. 
6.6.6  AC Fail Report 
This option allows you to specify a delay time, before reporting the power 
failure to the CS, in which time power may be restored. The time is set to 0 
(disabled) by default. 
Power (AC) failure is indicated by the Power LED, which flashes green. 
To set up AC fail report: 
1.  Using the numeric keypad, set the time between 1–240 minutes, or set it 
to 0 to disable the option. 
2.  Press Enter to confirm and save your selection. 
6.6.7  Fax Defeat 
When calling the system, fax and answering machines may need to be 
overridden. This menu specifies whether to enable or disable this override. By 
default, this option is disabled. 
To set up Fax Defeat: 
1.  Using the Menu button, Enable or Disable the option. 
2.  Press Enter to confirm. 