RS232 Protocol

1
Rotel A11
RS232 ASCII Controller Command List
The A11 supports an ASCII based RS232 protocol. The RS232 hardware does not
support flow control so care needs to be take when sending and receiving data to avoid
packet loss.
All commands sent to the attached Rotel device must have a terminating “!” character.
Example Command: power_on!
Note: Do not include any spaces in the command, and do not include a carriage return
or line feed after the command, only the “!” terminating character.
Status information from the attached Rotel product will have a terminating “$” character.
It is up to the sending/receiving control application to properly parse and process the
packets.
Connection Settings
Baud Rate
Parity
Valid Data Bits
Stop Bit Value
Handshaking
Data Type
115200
N
8
1
None
String
Communication Protocol
Command and response messages are included on the following pages.
Automatic status update information can be enabled/disabled using the
rs232_update_on” and “rs232_update_offcommands.
With RS232 update set to ON, any status changes to the unit will be transmitted via
RS232. With RS232 update set to OFF, the unit will not send any feedback unless polled
by the controller.
Date
Update Description
December 18, 2018
Original Specification