P5 Stereo Control Amplifier Préamplificateur Stéréo Stereo-Vorverstärker Preamplificador Estereofónico Stereo-regelversterker Preamplificatore Stereo Stereokontrollförstärkare Предварительный стерео усилитель Owner’s Manual Manuel de l’utilisateur Bedienungsanleitung Manual de Instrucciones Gebruikershandleiding Manuale di istruzioni Instruktionsbok Инструкция пользователя
P5 Stereo Control Amplifier 2 Important Safety Instructions Notice The RS232 connection should be handled by authorized persons only. WARNING: There are no user serviceable parts inside. Refer all servicing to qualified service personnel. WARNING: To reduce the risk of fire or electric shock, do not expose the unit to moisture or water. Do not expose the unit to dripping or splashing. Do not place objects filled with liquids, such as vases, on the unit.
English 3 Figure 1: Controls and Connections Commandes et Branchements Bedienelemente und Anschlüsse Controles y Conexiones 1 Bedieningselementen en aansluitingen Controlli e connessioni Kontroller och anslutningar Органы управления и разъемы 3 2 6 5 7 r t 8 90 - = q w y u io p [ ] 4 e \ a s
P5 Stereo Control Amplifier 4 Figure 2: RR-RH6 Remote Control Télécommande infrarouge RR-RH6 Fernbedienung RR-RH6 Mando a Distancia RR-RH6 Afstandsbediening RR-RH6 Telecomando RR-RH6 RR-RH6 fjärrkontroll Пульт ДУ RR-RH6 A G H B C K D E F
English 5 Figure 3: Analog Input and Output Connections Branchements des entrées et sorties analogiques Analoge Ein- und Ausgangsanschlüsse Entradas y Salidas Analógicas Analoge ingangen en uitgangen Collegamenti ingressi ed uscite analogici Anslutningar för analoga in- och utgångar Аналоговые входы и выходы Phono R L GND Michi P5 Rotel RCD-1572 CLASS 1 LASER PRODUCT APPAREIL LASER DE CLASSE 1 RP-565D Michi S5
P5 Stereo Control Amplifier 6 Figure 4: B alanced (XLR) Input and Output Connections Branchements des entrées et sorties symétriques (XLR) Symmetrische Ein- und Ausgangsanschlüsse (XLR) Entradas y Salidas Balanceadas (XLR) Gebalanceerde ingangen (XLR) en uitgangen Collegamenti ingressi ed uscite bilanciati (XLR) Balanserade in- och utgångar (XLR) Балансные (XLR) входы и выходы Rotel RCD-1572 CLASS 1 LASER PRODUCT APPAREIL LASER DE CLASSE 1 RP-565D Michi P5 Michi S5
English 7 Figure 5: Digital Inputs and 12V Trigger Output Entrées numériques et Branchements des sorties trigger 12 V Digitaleingänge und 12V TRIG-Ausgang Entradas Digitales y Salida para Señal de Disparo de 12V Digitale ingangen en 12V trigger-uitgang Collegamenti ingressi digitali e segnali Trigger 12 V Anslutningar för digitala ingångar och 12-volts styrsignaler Цифровые входы и 12-В триггерный выход Rotel RCD-1572 CLASS 1 LASER PRODUCT APPAREIL LASER DE CLASSE 1 RP-565D Michi P5 Computer Audio P
P5 Stereo Control Amplifier Important Notes When making connections be sure to: 4 Turn off all the components in the system before hooking up any components, including loudspeakers. 4 Turn off all components in the system before changing any of the connections to the system. It is also recommended that you: 4 Turn the volume control all the way down before the amplifier is turned on or off.
English 9 Contents Getting Started Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 1: Controls and Connections 3 Figure 2: RR-RH6 Remote Control 4 Figure 3: Analog Input and Output Connections 5 Figure 4: Balanced (XLR) Input and Output Connections 6 Figure 5: Digital Inputs and 12V Trigger Output 7 Important Notes 8 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P5 Stereo Control Amplifier 10 Cables Be sure to keep the power cords, digital signal cables and regular audio signal cables in your installation away from each other. This will minimize the chance of the regular audio signal cables picking up noise or interference from the power cords or digital cables. Using only high quality, shielded cables will also help to prevent noise or interference from degrading the sound quality of your system.
English Line Level Inputs 90- See Figure 3 The CD, Tuner, and Aux inputs of the control amplifier are analog “line level” inputs. These inputs are for connecting components such as CD players or other audio playback devices with an analog audio output. The left and right channels are clearly labeled and should be connected to the corresponding channels of the source component. The Left connectors are white, the Right connectors are red.
P5 Stereo Control Amplifier 12 For additional information on the connections, software, and operating codes for computer control of the P5, contact your authorized Michi dealer. PC-USB Input i See Figure 5 Connect this input using the supplied USB cable to the PC-USB socket of your computer. The P5 supports both USB Audio Class 1.0 and USB Audio Class 2.0 modes. Windows computers do not require installation of a driver for USB Audio Class 1.0 and support playback of audio up to 96k Hz sampling rates.
English NOTE: All Michi products will respond to the same Power On and Off commands to simplify the power control when multiple products are installed. To control the power using the IR remote follow the instructions above and point the remote control at the Michi products. If a unit does not respond to a power on or off from the IR remote simply PUSH or PUSHHOLD the power button again to resend the desired command. SETUP B: The SETUP button activates the OSD setup screen on the front display.
P5 Stereo Control Amplifier 14 Network Configuration SETUP SETUP Input SOURCE Name Enabled Volume Audio Mode Bass - 0 1 8 9 A H I J Q R S Z 2 B K T Esc 4 D M V 3 C L U Status 5 E N W 6 F O X 7 G P Y 1. Press the T/ D arrow buttons on the remote control to change the first letter, scrolling through the list of available characters. 2. Press the Enter K button on the remote control to confirm that letter and move to the next position. 3.
English 15 Press the SETUP B button on the remote control to exit the setup menu or select Back to return to the main menu. Audio Configuration SETUP NOTE: When the Signal Sense function is activated, the P5 will consume additional power in signal sense standby mode. When Selected AUDIO NOTE: When the P5 enters standby mode via the remote control, the Signal Sense function will not operate until the unit detects the audio has stopped for the minimum 10 minute time-out period.
P5 Stereo Control Amplifier 16 Troubleshooting System Configuration SETUP SYSTEM PC-USB Version Software Version Disabled Auto Power Off 20 Mins Software Update 1 Hour USB Power Factory Defaut 2 Hours 5 Hours Back 12 Hours This System menu in the Setup menu, provides the following options, selected by placing the highlight on the desired line using the T/ D arrow buttons and pressing the Enter K button. This action displays the right side options allowing changes.
English 17 Specifications Total Harmonic Distortion (20 Hz - 20k Hz) < 0.002% Digital Section Intermodulation Distortion (60 Hz : 7 kHz, 4:1) < 0.002% Frequency Response 20Hz - 20kHz (±0.3 dB, Max) Signal to Noise Ratio (IHF “A” weighting) 100 dB Input Sensitivity / Impedance Phono Input (MM) 2.5 mV / 47k ohms Input Sensitivity / Impedance 0dBFS / 75 ohms Phono Input (MC) 250 uV / 100 ohms Digital Output 0.
Rotel Global Office Room 1903, 19/F., Dominion Center 43-59 Queen’s Road East Wanchai Hong Kong Tel: 852 2793 9378 Fax: 852 3583 5035 Rotel USA Sumiko 6655 Wedgwood RD N, Suite 115 Maple Grove, MN 55311 USA Phone: (510) 843-4500 (option 2) E-mail: service@sumikoaudio.net Rotel Canada Kevro International 902 McKay Rd.