Owners Manual

15
• BLUETOOTH VOL: VARIABLE (disabled) is factory default.
NOTE: The Volume knob on the front panel and Volume +/‑ buttons on
the IR remote are disabled when the volume is Fixed. To disable this
feature set the Fixed Volume level to “Variable”.
PC-USB AUDIO CLASS: Change supported PC-USB Audio Class of the
attached device.
NOTE: Some computers attached to the PC‑USB do not support USB
Audio Class 2.0 and do not support 32 bits /384 kHz audio playback.
If needed the PC‑USB can be configured for USB Audio Class 1.0.
Please refer to your computer operating system for details.
PC-USB AUDIO MODE: Change PC-USB Audio mode to support MQA
and PCM Audio up to 24bits or PCM Audio Only up to 32bits. When
32B ONLY is selected MQA audio is not supported. To playback MQA
the MQA/24B option must be selected.
Valid settings include: MQA/24B (Default), PCM 32B.
NETWORK: Shows the network connection status and to view/congure
the network settings. If the network is properly congured and attached,
“Connected” will be displayed. To view or modify the network settings,
press the ENTER button.
The RA-1592MKII supports both DHCP and STATIC IP addressing. Select
the desired IP address method and press ENTER.
If DHCP is selected you can refresh IP address by pressing ENTER or press
MENU to view IP address information. Press the MENU button to toggle
through IP address settings. If the IP address is renewed the network will
be tested and connection status reported.
If STATIC IP address mode is selected you must congure all settings for the
network including IP Address, Subnet Mask, Gateway and DNS Server. Use
the up/down/left/right or +/- buttons to adjust the values and press ENTER
to move to the next value. When the proper IP information is congured
press MENU to go to the next setting. After entering the STATIC IP address
information the network will be tested and connection status reported.
NOTE: For more information regarding network connection please
contact your authorized Rotel dealer.
NOTE: A network connection is not required for the RA‑1592MKII to
operate.
MAIN: This shows the current software version loaded into the RA-
1592MKII. The software can be updated if the RA-1592MKII is properly
connected to the Internet.
• Press ENTER to check if a new software version is available.
If a new software version is available press the + button on the front
panel or the up/right button on the remote control to select YES then
press ENTER button to begin the software update process.
The new software will be downloaded from the Internet. The RA-
1592MKII will power cycle when the software update is complete.
NOTE: Do NOT power off the RA‑1592MKII during the software
update process.
NOTE: It is recommended to Reset Factory Defaults after the software
update is complete.
• PC-USB: This shows current loaded software version for PC-USB processor.
SIGNAL SENSE: Check if an audio signal is present on the congured
Signal Sense input. The RA-1592MKII monitors the data stream to
determine if there is audio. If there is no audio detected for 10 minutes,
the RA-1592MKII will enter Signal Sense Power Mode. When in Signal
Sense Power Mode and the RA-1592MKII detects audio on Signal Sense
input, the unit will automatically power on. To disable this function, select
the OFF option which is the factory default setting.
NOTE: When the SIGNAL SENSE function is activated, the RA‑1592MKII
will consume additional power in signal sense standby mode.
NOTE: Due to local power consumption regulations the SIGNAL SENSE
function is not available in all markets.
FACTORY DEFAULT: This sets the unit back to the original state as when
it left the factory. Press the + button on the front panel or RIGHT arrow
button on the remote control to select <YES> then press the “ENTER”
button on the front panel or on the remote control.
NOTE: All previously configured options will be erased and reset to
the factory default settings.
Troubleshooting
Most difculties in audio systems are the result of incorrect connections,
or improper control settings. If you encounter problems, isolate the area
of the difculty, check the control settings, determine the cause of the fault
and make the necessary changes. If you are unable to get sound from the
RA-1592MKII, refer to the suggestions for the following conditions:
Power Indicator Is Not Illuminated
The Power Indicator ring around the power button and the basic items in
the Display window should be illuminated whenever the RA-1592MKII is
plugged into the wall power outlet and the POWER switch is pushed in. If
it does not light, test the power outlet with another electrical device, such as
a lamp. Be sure the power outlet being used is not controlled by a switch
that has been turned off.
Fuse Replacement
If another electrical device works when plugged into the power outlet,
but the Power Indicator still will not illuminated when the RA-1592MKII is
plugged into the wall outlet, it indicates that the internal power fuse may
have blown. If you believe this has happened, contact your authorized Rotel
dealer to get the fuse replaced.
No Sound
Check the signal source to see if it is functioning properly. Make sure the
cables from the signal source to the RA-1592MKII inputs are connected
properly. Check the wiring between the RA-1592MKII and the speakers.