RS232 Protocol
4
OTHER COMMANDS
factory_default_on!
Set all user settings back to
factory defaults.
power=on!
INPUT SELECTION COMMANDS (V2.45 and newer)
input_sel_auto! Set input select mode to Auto input_sel_mode=auto!
input_sel_digital! Select optical input input_sel_mode=digital!
input_sel_analog! Select analog input input_sel_mode=analog!
STATUS REFRESH COMMANDS
display_update_auto! Set Status Update to Auto display_update=auto!
display_update_manual! Set Status Update to Manual display_update=manual!
Section 2: Feedback Request Command List
Command:
get_product_type!
Description:
Request the product type
Return String:
product_type=##,text
Return Description:
Rotel product type name, must include 2 digit length of text string at
beginning followed by "," and text string (no terminating character)
Example:
product_type=08,RKB-850
Command:
get_product_version!
Description:
Request the main CPU software version
Return String:
product_version=##,text
Return Description:
Rotel main CPU software version, must include 2 digit length of text string at
beginning followed by "," and text string (no terminating character)
Example:
product_version=06,V1.2.2
Command:
get_display_update!
Description:
Request status update
Return String(s):
display_update=auto! / display_update=manual!
Return Description:
Status of if the status refresh is automatic or manual
Example:
display_update=auto!
Command:
get_current_power!
Description:
Request current power status
Return String(s):
power=on! / power=standby! / power=SignalSenseMode!
Return Description:
Current power status. If in Signal Sense mode will return SignalSenseMode
instead of on/standby.
Example:
power=on!
Command:
get_input_sel_mode!
Description:
Request current input select mode (Requires Main SW V2.45 or later)
Return String(s):
input_sel_mode=auto! / input_sel_mode=digital! / input_sel_mode=analog!
Return Description:
Current input selection mode.
Example:
input_sel_mode=digital!