A12 Owner’s Manual Manuel de l’utilisateur Bedienungsanleitung Manual de Instrucciones Gebruikershandleiding Manuale di istruzioni Instruktionsbok Инструкция пользователя Stereo Integrated Amplifier Amplificateur Stéréo Intégré Stereo-Vollverstärker Amplificador Integrado Estereofónico Geïntegreerde stereoversterker Amplificatore integrato stereo Integrerad stereoförstärkare Интегрированный стерео усилитель
A12 Stereo Integrated Amplifier 2 Important Safety Instructions Notice You must allow a minimum 10 cm or 4 inches of unobstructed clearance around the unit. The RS232 connection should be handled by authorized persons only. WARNING: There are no user serviceable parts inside. Refer all servicing to qualified service personnel. WARNING: To reduce the risk of fire or electric shock, do not expose the unit to moisture or water. Do not expose the unit to dripping or splashing.
Figure 1: Controls and Connections Commandes et Branchements Bedienelemente und Anschlüsse Controles y Conexiones Controlli e connessioni De bedieningsorganen en aansluitingen Kontroller och anslutningar Органы управления и разъемы 1 2 34 5 6 7 POWER SPEAKERS PHONES A12 A B PHONO TUNER CD USB OPT COAX AUX PC-USB BT MENU 5V / 2.1A 8 0 - =q w e p r t y u [ 9 i ] o \ a
A12 Stereo Integrated Amplifier 4 Figure 2: Remote Control RR-AX1400 Télécommande infra-rouge RR-AX1400 Fernbedienung RR-AX1400 Mando a Distancia RR-AX1400 Telecomando RR-AX1400 De afstandsbediening RR-AX1400 Fjärrkontroll RR-AX1400 Пульт ДУ RR-AX1400 A J B K C L M D E F N G H I
Figure 3: Preamp Input and Speaker Output Connections Branchements des entrées sources et sorties enceintes acoustiques Anschlussdiagramm Conexiones para Entrada de Señal y Salida a las Cajas Acústicas Collegamenti ingressi e diffusori De signaalingangen en de luidsprekeruitgangen Signal- och högtalaranslutningar Подсоединение источников сигнала и акустических систем Amplifier A12 CD PLAYER PHONO
A12 Stereo Integrated Amplifier 6 Figure 4: Digital Input Connections Branchements Entrées numériques Digitaleingänge-Anschlüsse Conexiones Entradas Digitales Digitale ingang verbinding Collegamenti ingressi digitali Anslutningar för digitala ingångar Подсоединение Цифровые входы Computer (Supplied) Amplifier A12 CD Player CD14 CLASS 1 LASER PRODUCT APPAREIL LASER DE CLASSE 1 MODEL NO.
Figure 5: Rotel Link and 12V Trigger Connections Branchements Rotel Link et trigger 12 V Rotel Link- und 12V-Trigger-Anschlüsse Conexiones Rotel Link y para Señal de Disparo de 12V De Rotel Link en 12V trigger aansluitingen Collegamenti Rotel Link e segnali Trigger 12 V Rotel Link-anslutning och 12 V-anslutning för styrsignal Подсоединение Rotel Link и 12-В триггерного сигнала Important! : The 12V trigger cables will override the Rotel Link commands.
A12 Stereo Integrated Amplifier 8 Figure 6: Front USB Input Entrée USB en face avant Frontseitiger USB-Eingang Entrada USB Frontal USB-ingang op het voorpaneel Ingresso USB frontale USB-port på fronten USB вход на передней панели POWER SPEAKERS PHONES A12 A B 5V / 2.
Important Notes When making connections be sure to: 4 Turn off all the components in the system before hooking up any components, including loudspeakers. 4 Turn off all components in the system before changing any of the connections to the system. It is also recommended that you: 4 Turn the volume control of the amplifier all the way down before the amplifier is turned on or off.
A12 Stereo Integrated Amplifier 10 Contents About Rotel Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 1: Controls and Connections 3 Figure 2: Remote Control RR-AX1400 4 Figure 3: Preamp Input and Speaker Output Connections 5 Figure 4: Digital Input Connections 6 Figure 5: Rotel Link and 12V Trigger Connections 7 Figure 6: Front USB Input 8 Important Notes 9 About Rotel. . . . . . . . . . . . . . . . . . . . . . .
A Few Precautions WARNING: To avoid potential damage to your system, turn off ALL the components in the system when connecting or disconnecting the loudspeakers or any associated components. Do not turn the system components back on until you are sure all the connections are correct and secure. Pay particular attention to the speaker wires. There must be no loose strands that could contact the other speaker wires, or the chassis of the amplifier. Please read this manual carefully.
A12 Stereo Integrated Amplifier 12 Power Switch 1A and Power Indicator 2 Phono Input - and Ground Connection (GND) 0 When the power switch is in the ON position, the remote control ON and OFF buttons may be used to activate the A12. In Standby mode the power LED is red, but the display is turned OFF. Line Level Inputs =qw Press the front panel Power Switch button 1 to turn the unit on. The Power Indicator light 2 is illuminated when the unit is on. Press Power Switch button again to turn the unit off.
Polarity and Phasing The polarity - the positive/negative orientation of the connections - for every speaker and amplifier connection must be consistent so all the speakers will be in phase. If the polarity of one connection is reversed, bass output will be very weak and stereo imaging degraded. All wire is marked so you can identify the two conductors. There may be ribs or a stripe on the insulation of one conductor.
A12 Stereo Integrated Amplifier 14 Bass and Treble Controls 9B Set the Bass or Treble controls from the front panel by pressing the MENU 9 button to the Bass and Treble Setting menu in sequence. Then press the - or + buttons to adjust the value. The Bass and Treble values range from -10 to +10. NOTE: These settings are saved permanently including after powering off the A12.
EXT REM IN Jack y This 3.5mm mini-jack receives command codes from industry-standard infrared receivers via hard-wired connections. This feature could prove useful when the unit is installed in a cabinet and the front-panel sensor is blocked. Consult your authorized Rotel dealer for information on these external repeaters and the proper wiring of a jack to fit the mini-jack receptacle. RS232 Connector i The A12 can be controlled via RS232 for integration with automation systems.
A12 Stereo Integrated Amplifier 16 USB, PC-USB, Optical 1, Optical 2, Coax 1, Coax 2, or Bluetooth. When enabled and the input with a Fixed Volume is selected, the Volume level will immediately be set to the specified level. Troubleshooting • AUX1 VOL: VARIABLE (disabled) is factory default. Most difficulties in audio systems are the result of incorrect connections, or improper control settings.
Specifications Continuous Power Output 60 watts/ch (20 - 20k Hz, < 0.03%, 8 ohms) Total Harmonic Distortion (20 Hz - 20k Hz, 8 ohms) < 0.03% Intermodulation Distortion (60 Hz : 7k Hz, 4:1) < 0.03% “Made for iPod,” and “Made for iPhone,” means that an electronic accessory has been designed to connect specifically to iPod or iPhone, respectively, and has been certified by the developer to meet Apple performance standards.
The Rotel Co. Ltd. Tachikawa Bldg. 1F., 2-11-4, Nakane, Meguro-ku, Tokyo, 152-0031 Japan Rotel of America Sumiko 6655 Wedgwood RD N, Suite 115 Maple Grove, MN 55311 USA Phone: (510) 843-4500 (option 2) E-mail: service@sumikoaudio.net Rotel Canada Kevro International 902 McKay Rd.
STEREO INTEGRATED AMPLIFIER A12 2 x 60 Watts of robust Class AB power Moving magnet phono input for turntable connection The A12 integrated amplifier displays the same clean lines and intuitive operation as the A14 with output power rated at 60 watts per channel RMS into 8 ohms. Rotel engineers begin their quest for uncompromising audio performance at the power supply. This is the heart of an amplifier and an area where considerable time and investment is spent.
STEREO INTEGRATED AMPLIFIER A12 SPECIFICATIONS Continuous Power Output (20 - 20kHz, < 0.03%, 8 ohms) 60 watts/ch Total Harmonic Distortion (20 Hz - 20 kHz at rated power) < 0.03% Intermodulation Distortion (60 Hz : 7kHz, 4:1) < 0.03% Frequency Response Phono Input 20Hz - 15kHz, ± 0.5dB Line Level Inputs 10Hz - 100kHz, ± 0.5dB Damping Factor (20 - 20,000 Hz, 8 ohms) 220 Digital Section Frequency Response 10Hz - 80kHz (± 3.
Technical Information October 18, 2019 ROTEL YModem Upgrade Manager V2.0.3 Software Upgrade Instructions Software update for Rotel products can be completed using the Rotel YModem software update utility via an RS232 connection. The step-by-step instructions below provide information on setup and configuration using a Windows PC. Items needed for upgrade 1. Windows-compatible x86 or x64 PC with serial port connection, or USB-to-serial adapter. 2. RS232 straight cable with DB-9 terminations. 3.
Upgrade Procedure 1. Download YModem Upgrade Manager V2.0.3 from ROTEL website. http://www.rotel.com/software-downloads 2. Connect the RS232 cable between the unit and the computer. 3. Launch the Rotel YModem Upgrade Manager computer program. It should be located in the folder labeled “Rotel YModem Upgrade Manager”. 4.
5. Press “Connect” on the program. The Connect button should grey out, and the Open button should become selectable. 6. Click the “Open” button. A window will open to locate the software update bin file which was included with the upgrade files. Browse to the location on the computer where this file was saved, select the file and click [Open] for next step. 7. Once the file has been selected, click the “Send Upgrade Request” button. Rotel Electronics Co., Ltd.
8. The front panel display of the unit should turn off and some text should appear in the window of the Ymodem program. 9. Click the Send Upgrade File” button to start the download. A file transfer window should appear as the file downloads to the unit. 10. Once the transfer is complete the file transfer window will disappear, and the text in the file transfer window will indicate the programming has completed and to turn power cycle the device. Rotel Electronics Co., Ltd.
11. Press “OK” to close the file transfer window, and then press “Close” to close the YModem Upgrade Manager. 12. Unplug the power cord, or push the front panel power toggle button to do a power cycle to complete the upgrade process. 13. If at any time the update is interrupted or failed, or the unit does not respond after upgrade – see the Troubleshooting section at the end of this document to try the procedure again. Rotel Electronics Co., Ltd.
Troubleshooting How to determine RS232 COM port: It is important when selecting the com port for updates and RS232 communication to be aware of what com port is being used on the PC for the upgrade, whether it be a built in serial port on the PC, or a USB to serial adapter. Selecting the incorrect com port in an update program or an RS232 terminal will result in communication errors. Common YModem error messages from incorrect com port settings are: “Unable to connect. Please verify COM port information.
Unable to Lunch on Windows 7/10: By default, Windows 7/10 has integrated .Net Framework 2.0/3.5 inside and user no need to manually install it, please check below configuration to make sure it is enabled in Windows 7 and 10 if unable to lunch the application 1. Press [WIN]+[R] keyboard shortcut to activate RUN dialog box, type “appwiz.cpl” to lunch “Programs and Features”. 2. Click “Turn Windows features on or off” to activate “Windows Features” dialog box. 3. Make sure below “.NET Framework 3.
Failed to Receive the File during upgrading: Generally, the upgrading requires a good RS232 communication, make sure a good enough RS232 or USB cable be used, a long external RS232 or USB cable possible led a bad electrical signal quality transferring during upgrading process. Check below options when you see below error message: 1. Check the RS232 or USB connection. 2. Check the RS232-to-USB convertor, or replace it by good one. 3.
Important for Windows XP: make sure you have the .NET FRAMEWORK 2.0/3.5 installed, in addition make sure you have the Windows Installer 3.1 installed before you installed the framework. 1. Access below link to download and install .Net Framework 2.0/3.5: https://www.microsoft.com/en-US/download/details.aspx?id=21 To download the full redistributable package, rather than the bootstrapper, click on the link below to start the download: .NET Framework 3.5 full package 2.
~~-~ I~- !I -\~"I;:"'- L~ ,......,, ••----,---::-- TiEL: Important Safety Instructions English Italiano These notes should be read with the owner's manual and its addendum and relates to safety instructions. Queste note sono parte integrante del manuale di istruzioni dell' apparecchio e sono relative all importanti informazioni di sicurezza.
English 2 WARNING: There are no user serviceable ~I ww,w,w•••• I & parts inside. Refer all servicing to qualified service personnel. WARNING : SHOCK HAZARD-DO NOT OPEN WARNING: To reduce the risk of fire or electric AVIS:RISOUE DE CHOC ELECTRIOUE-NE PAS OWRIR shock, do not expose the unit to moisture or water. Do not expose the unit to dripping or splashing. Do not place objects filled with liquids, such as vases, on the unit. Do not allow foreign objects to get into the enclosure.
r L,; :{1) . '! R □ TEL: ' The Rotel Co. Ltd. Rotel Deutschland Tachikawa Bldg. 1F., Vertrieb: B&W Group Germany GmbH 2-11-4, Nakane, Meguro-ku, Kleine Heide 12 Tokyo, 152-0031 D-33790 Halle/Westf., Deutschland Japan Tel.: 05201 / 87170 Fax: 05201 I 73370 Rotel of America 54 Concord Street q,OO#'t~ North Reading, MA 01864-2699 USA ~rlfi*f.lGIK#'t{fltl,-=fl'fll&~'B'J ffilhl: 9'1 m1*!ti~1firm~tfit*ffl.
Register Today R □ TEL Please take a moment and register your Rotel product on our website: http://www.rotel.com/product-registration. If your Rotel product needs service the registration information can help expedite the repair process. You may also request to be included in future product information emails, if desired . Please note your information will not be provided to any third parties or used for unauthorized marketing activities.
North American Limited Warranty Garantie limitee pour I' Amerique du Nord This product has a warranty against faulty material and workmanship when used in normal domestic operation for the purpose for which it was designed and is subject to the following conditions: Ce produit possede une garantie contre les defauts de fabrication sur les pieces et la main-d'oeuvre lorsqu'utilise a la maison aux fins pour lesquelles ii a ete con~u sous reserve des conditions suivantes: The product is acquired from an au