16
RA‑1572 Stereo Integrated Amplier
circuits monitor the temperature of the output devices and shut down the
amplier if temperatures exceed safe limits.
Most likely, you will never see this protection circuitry in action. However,
should a faulty condition arise, the amplier will stop playing and will
display “AMP PROTECTION“ on the front panel.
If this happens, turn the amplier off. Let it cool down for several minutes,
and attempt to identify and correct the problem that caused the protection
circuitry to engage. When you turn the amplier back on, the protection
circuit will automatically reset.
In most cases, the protection circuitry activates because of a fault condition
such as shorted speaker wires, or inadequate ventilation leading to an
overheating condition. In very rare cases, highly reactive or extremely low
impedance speaker loads could cause the protection circuit to engage.
If the protection circuitry triggers repeatedly and you are unable to isolate
and correct the faulty condition, contact your authorized Rotel dealer for
assistance in troubleshooting.
Settings Menu
You can access the settings menu from the front panel by pressing the
MENU
9
button or the SETUP D button on the remote. You can change
the value of the selected option by pressing the +/- buttons on the front
panel or up/down/left/right E arrow buttons on the remote. Step through
the sub-menus by pressing the MENU
9
button on the front panel or the
SETUP D button on the remote.
• TONE Control: TONE BYPASS ON/OFF, BASS level and TREBLE levels
can be changed to desired settings. Press the ENTER button on the front
panel or on the remote to toggle between the tone setup options. (For
more information on Tone Control refer to the Tone Control Bypass, Bass
and Treble control sections.)
NOTE: These settings are stored permanently even after the RA‑1572
is powered off.
• BALANCE: Change left/right balance (For more information on Balance
sections refer to the Balance Control section).
NOTE: This setting is stored permanently even after the RA‑1572 is
powered off.
• DIMMER: Dims the front display.
NOTE: This setting is stored permanently even after the RA‑1572 is
powered off.
• POWER LED: Dims the Power LED and the LEDs above the Speaker Selector
buttons on the front panel.
NOTE: This setting is stored permanently even after the RA‑1572 is
powered off.
• POWER ON MAX VOLUME: This sets the maximum volume level when
the unit is turned ON. “45” is the factory default.
NOTE: Power On Max Volume settings do not apply to sources
congured with Fixed Gain.
• POWER OPTION: Enables the RA-1572 to be controlled via the network
port when attached to an automation system. The power consumption is
higher in Quick Power mode. If network control is not required select the
Normal Power mode. “Normal” is the factory default.
Valid settings include: Normal, Quick.
NOTE: When the POWER OPTION is configured to Quick, the RA‑
1572 will consume additional power in standby mode.
• USB POWER: This option allows the rear panel USB connector to provide
power, even when the RA-1572 is in standby mode.
To enable the continuous power mode select the ALWAYS option. To provide
power only when the RA-1572 is powered on, select the NORMAL option.
The default for USB POWER is set to NORMAL.
NOTE: The front panel power button must be in the ON position to
supply power to the rear panel USB connector.
NOTE: When the USB POWER is configured to ALWAYS the RA‑1572
will consume additional power in standby mode to supply USB power.
• AUTO POWER OFF: The RA-1572 can be congured to automatically
power off if unused for a specied period. If no changes are made to the
unit within the specied “Auto Power Off” time the unit will automatically
go to STANDBY mode. The Auto Power Off timer will be restarted if
changes are made to the volume, source or playback. The default for
Auto Power Off is set to DISABLE.
Valid settings include: DISABLE, 1 HOUR, 2 HOURS, 5 HOURS, 12 HOURS.
• FIXED GAIN: Congures a Fixed Volume level for a specied input. To
enable this feature press the +/- buttons to select the desired xed volume
level for Aux, USB, PC-USB, Optical 1, Optical 2, Coax 1, Coax 2 or
Bluetooth. When enabled and the input with a Fixed Volume is selected,
the Volume level will immediately be set to the specied level.
Valid settings include: VARIABLE, FIXED 01-95, FIXED MAX.
• AUX VOL: VARIABLE (disabled) is factory default.
• USB VOL: VARIABLE (disabled) is factory default.
• PC-USB VOL: VARIABLE (disabled) is factory default.
• OPT1 VOL: VARIABLE (disabled) is factory default.
• OPT2 VOL: VARIABLE (disabled) is factory default.
• COAX1 VOL: VARIABLE (disabled) is factory default.
• COAX2 VOL: VARIABLE (disabled) is factory default.
• BTOOTH VOL: VARIABLE (disabled) is factory default.