RS232 Protocol
3
T11 ASCII
Command Description
Unit Response
FM / DAB PRESET COMMANDS
memory!
Select memory for saving presets
n/a
call_fm_preset_n!
Recall FM Preset n (n = 01 - 30)
fm_preset_n=##,text
call_dab_preset_n!
Recall DAB Preset n (n = 01 - 30)
dab_preset_n=##,text
OTHER COMMANDS
dimmer!
Toggle display dimmer
dimmer_#!
dimmer_0!
Set display to brightest setting
n/a
dimmer_1!
Set display to dimmer level 1
n/a
dimmer_2!
Set display to dimmer level 2
n/a
dimmer_3!
Set display to dimmer level 3
n/a
dimmer_4!
Set display to dimmer level 4
n/a
dimmer_5!
Set display to dimmer level 5
n/a
dimmer_6!
Set display to dimmest setting
n/a
DISPLAY REFRESH COMMANDS
display_update_auto!
Set Display Update to Auto
display_update=auto!
display_update_manual!
Set Display Update to Manual
display_update=manual!
Section 2: Feedback Request Command List
Command:
get_display!
Description:
Request the entire display to be sent
Return String:
display=###,text
Return Description:
Current display data; must include 3 digit length of text string at beginning
followed by "," and text string (no terminating character)
Example:
display=020, Sample Text
Command:
get_display1!
Description:
Request display line #1 to be sent
Return String:
display1=##,text
Return Description:
Current display line 1, must include 2 digit length of text string at beginning
followed by "," and text string (no terminating character)
Example:
display1=20, Sample Text
Command:
get_display2!
Description:
Request display line #2 to be sent
Return String:
display2=##,text
Return Description:
Current display line 2, must include 2 digit length of text string at beginning
followed by "," and text string (no terminating character)
Example:
display2=20, Sample Text