CD TUN AV MP3 OFF V MUTE V RKP-200 Learning Keypad RHB-200 Keypad Connecting Hub
1. RKP-200/RHB-200 RKP-200 Keypad � � � CD TUN AV MP3 ZONE IN � � OFF V MUTE V ZONE OUT � 2.
3.
RKP-200/RHB-200 4.
5.
RKP-200/RHB-200 Contents 1. RKP-200 Keypad 2. RHB-200 Connecting Hub 3. Connecting Keypads 4. Connecting RHB-200 5. Clone setup 2 2 3 4 5 Introduction .............................................................. 7 Key Features 7 RKP-200 Overview ................................................... 7 Device Buttons 7 Command Buttons 7 Multi-function Buttons 7 IR Sensor 7 Output Connector 7 Input Connector 7 DIP Switches 7 RESET Button 7 RHB-200 Overview ................................................
Introduction The RKP-200 Keypad and RHB-200 Connecting Hub provide an integrated system that allows control of Rotel multi-zone systems from wall mounted keypads in remote zones. Key Features • Programmed to operate Rotel multi-zone receivers, DVD players, CD players, and AM/FM tuners. • Learning function to teach the RKP-200 commands from other remotes. Multi-step SMART programming for automatic sequences. • System allows control from up to four zones.
RKP-200/RHB-200 +12V DC input The power connector receives +12V signal when AC power supply is plugged into a wall outlet. Clone Input RJ-45 modular jack accepts CAT-5 cable from keypad during cloning configuration. Zone Inputs Four RJ-45 modular jacks accept CAT-5 cables from keypads in up to four zones. Zone IR Outputs Four 3.5mm mini-jacks send IR signals to the zone IR inputs on a Rotel receiver. Common IR Outputs Six 3.
Mounting the Keypads Once all of the keypads are connected, programmed, and tested, finish the installation by installing them into electrical boxes. NOTE: Purchase decorative switchplate covers to match those used in the room for light switches. The RKB-200 is not supplied with decorative switch plate covers because there is no way to know which style or color will match in custom installations. The exact installation steps may vary depending on the style of switch plate covers you purchase.
RKP-200/RHB-200 Operating the Keypads The keypads are preprogrammed to operate the Rotel RX-1052 multi-zone receiver and the following source components: Rotel CD Players: RCD-1072 & RCC-1055 Rotel Tuner: RX-1052 built-in tuner Rotel DVD Player: RDV-1092/RDV-1060 MP3 Players: Navipod and the most popular brands of portable players Although the keypads can be customized with learned commands, there is no need to do so when used with components listed above.
Backlighting As delivered from the factory, the keypads have automatic backlighting for the device buttons and the button. When a device button is pressed, the backlighting for that button remains lit to indicate the currently selected device. Configuring the keypads With the default factory configuration, the keypads are ready to use in a system with Rotel components as described in the Operating the Keypads section of the manual. However, the keypads can be customized in several ways during setup.
RKP-200/RHB-200 Details of the switch settings are provided with the instructions for each configuration option, but here is a summary: SW1: Used for invisible layer command programming for the CD device. SW2: Used for invisible layer command programming for the TUN device. SW3: Used for invisible layer command programming for the AV device. SW4: Used for invisible layer command programming for the MP3 device. SW5: In the ON position, enables the ton as an additional device key.
To make the only additional device button, put SW5 in the ON position: To make the only additional device button, put SW6 in the ON position: To make both and additional device buttons, put both SW5 and SW6 in the ON position: For no additional device buttons, put both SW5 and SW6 in the OFF position: as device If you have designated and/or buttons (SW5 and/or SW6 in the ON position), these buttons cannot be used to learn commands.
RKP-200/RHB-200 5. Aim the handheld remote at the oval sensor on the front of the keypad from a distance of approximately 1 inch (25 mm). Press and hold the button on the handheld remote with the command to be learned (the PAUSE button, in this example). 6. If the command is successfully learned, the button will flash twice. Six flashes indicate that the learning failed. If the learning failed, repeat from Step 4. 7.
4. Within 30 seconds, press the keypad command button that you wish to learn (in this example, the button). The backlighting on the button turns on and the keypad is ready to receive the IR code. It will flash six times if an improper button is pressed (for example, a device button that cannot be learned). 5. Aim the handheld remote at the oval sensor on the front of the keypad from a distance of approximately 1 inch (25 mm).
RKP-200/RHB-200 Programming a SMART Sequence with Invisible Layer Commands To include invisible layer commands in a SMART sequence, substitute the following steps for Step 4 in the preceding instructions: • Put SW1, SW2, SW3, or SW4 in the ON position to select the invisible layer where the desired command is stored: pad in ZONE 1. While this keypad is receiving cloned data, the ZONE 1 LED on the front of the RHB-200 flashes red.
2. Using a small flat blade screwdriver, release the four tabs on the sides of the module, releasing the keypad cover. 3. Once the keypad cover has been removed, pull a button off and replace it with one of the optional buttons.
The Rotel Co. Ltd. 10-10 Shinsen-Cho Shibuya-Ku Tokyo 150-0045 Japan Phone: +81 3-5458-5325 Fax: +81 3-5458-5310 Rotel of America 54 Concord Street North Reading, MA 01864-2699 USA Phone: +1 978-664-3820 Fax: +1 978-664-4109 Rotel Europe Dale Road Worthing, West Sussex BN11 2BH England Phone: +44 (0)1903 221600 Fax: +44 (0)1903 221525 Rotel Deutschland Kleine Heide 12 D-33790 Halle/Westf. Germany Phone: +49 05201-87170 Fax: +49 05201-73370 www.rotel.