User's Manual

1669-R RFD OPERATOR MANUAL REV. PP1
40
7. BASIC TROUBLESHOOTING IN THE FIELD.
7.1. REMOTE UNITS.
7.1.1. ON and SAFE lights do not illuminate when the Antenna Assembly is
installed.
a) Check Antenna Assembly and make sure it is seated, “clicks” on to the connector.
b) Recharge the battery.
c) Try a different Antenna Assembly.
7.2. CONTROLLER UNIT.
7.2.1. ON Light does not stay on.
a) Check Antenna Assembly and make sure it is seated, “clicks” on to the connector.
b) Press and hold the “ON” switch for 5 seconds.
c) Controller Unit battery needs to be recharged.
7.2.2. Command receipt is not confirmed by Remote Unit.
a) Remote Unit is more than 1 mile from Controller Unit.
b) If the Remote Unit is less than 1 mile away from the Controller Unit.
Check for damage to Controller Unit Antenna Assembly.
Try a different Antenna Assembly on the Controller Unit.
Move at least 25 feet in any direction and try again.
Reposition the Remote Unit if:
The antenna is not positioned vertically.
The antenna is next to another radio antenna.
The antenna is surrounded by metallic objects.
Use optional magnetic mount antenna for improved gain. This antenna is
available by special order only.
7.3. RADIO SHOCK TUBE INITIATOR.
7.3.1. Unit will not ignite the shock tube.
a) The igniter tip may be worn or damaged. Replace tip.
b) The shock tube may be damaged from moisture. Try a fresh cut or replace the
tubing. Ensure the tube covers the entire needle. Ensure both the needle and
the tube are dry when mating.