User's Manual
1669-R RFD OPERATOR MANUAL REV. PP1
63
>R
>Read Coefficients
System Type 92
Version 1.00
Checksum FEFE
DOM 08-14-2000
S/N 12345
System Address 57383
Unit ID 2
Tx Freq. 154.5700 MHz
>
>System Type: The ‘9’ in system type of the above example indicates that it is a unit
from a 1669 system. The ‘2’ indicates that the Unit is a Remote. A 1669 Controller
would be displayed as 91.
Version: This is the version of the firmware for the unit. The system type and version
are for information only and are not changeable.
10.3.2. Controller Unit Programming Procedure:
• Plug the Test Box probe into the controller antenna Connector.
• Press Remote selector switch 3 while turning Controller Unit on to place
Controller Unit in the programming mode.
• Program Controller (frequency is the only parameter programmable; the other
parameters can be read).
10.3.3. Remote Unit Programming Procedure:
• Plug the Test Box probe into the Remote Unit antenna connector.
• The steady red, flashing yellow, and steady green lights indicate the Remote Unit
is in the programming mode.
• Program the Remote Unit: (frequency, unit id, and address are programmable).