11. BATTERY MAINTENANCE.
The battery packs will provide optimum performance and maximum life when the
following recommendations are adhered to.
11.1. BATTERY TEMPERATURE:
For maximum efficiency charge batteries when they are between 10 and 30 degrees
Celsius. DO NOT attempt to CHARGE BATTERIES that are BELOW 0 degrees or
ABOVE 40 degrees Celsius. Permanent damage to batteries and or equipment may
result.
11.2. PRE-OPERATION:
Use the Battery Charger Assembly to discharge and then charge the battery of each
unit.
11.3. PERIODIC:
Twice every two months use the Battery Charger Assembly to discharge and then
charge the battery of each unit.
11.4. ANNUAL:
Have the battery packs replaced every 3 years or 300 charge / discharge cycles,
whichever comes first.
11.5. EXTENDED NON-USE:
If the battery has not been discharged and charged within four months, repeat the
discharge / charge cycle four times and check the battery capacity prior to operational
use. Do not exceed storage temperature guidelines as it may reduce battery capacity
and/or cause physical deterioration of battery components.
Storage Time Storage Temperature (deg. C)
<30 days -20 to +50
30 - 90 days -20 to +40
>90 days -20 to +30