User's Manual

1669-R RFD OPERATOR MANUAL REV. PP1
78
11.6. BATTERY CAPACITY CHECK:
Fully charge the battery.
Press the “BATTERY DISCHARGE” switch.
Note the amount of time from when the “BATTERY DISCHARGE” switch was
pressed until the red DISCHG light turns off.
A good battery will take approximately three hours to discharge. Replace the
battery pack if the discharge time is less than two and one half hours and the
discharge / charge cycle has been repeated four times.