WARNING Ensure that blasting caps are not connected to any of the Remote
Units during bench test.
WARNING This is a sensitive electronic radio system and it may be damaged.
WARNING Do not use the Controller Unit within 100 feet of explosives, blasting
caps, or wires leading to them. The controller signal is 5 watts, which can cause
detonation of caps if within 100'. The 5 watt controller complies with the Recommended
Table of Distances established by the Institute for the Makers of Explosives (IME) when
placed beyond 100 feet of explosives.
WARNING Do not engage in RFD communications with the Remote Units when
they are connected to explosive charges until the shot is prepared and all personnel are
clear. The Remote Unit complies with the Recommended Table of Distances
established by the Institute for the Makers of Explosives (IME) when placed 25 feet or
more from blasting caps or wires leading to them. For further information, refer to the
Institute for the Makers of Explosives Publication no. 20, Part II, Section (1).
WARNING Do not touch the igniter tip jacks on the Radio Shock Tube Initiator
(RSTI) when armed or firing. Lethal voltages may be present.
CAUTION Do not assume the Disarm command has been received by the
Remote Unit unless DISARMED status is confirmed with a steady DISARMED light for
that Remote Unit on the Controller Unit display panel. If distance appears to be the
problem, move closer to the Remote Unit following standard procedures for this type of
situation. The “STATUS” and/or “DISARM” switches may be pressed repeatedly as the
Remote Unit is approached. Maintain a safe distance from the Remote Unit. Do not
approach the Remote Unit until DISARMED status is confirmed with a steady
DISARMED light for that Remote Unit on the Controller Unit display panel. Under no
conditions should the “FIRE” switch be pressed as the Remote Unit is approached. DO
NOT bring the Controller Unit closer than 100 feet to blasting caps, wires connected to
blasting caps, or other explosives.
CAUTION All units must be thoroughly tested and the batteries fully charged prior
to operational use.
CAUTION Unequal air pressure inside the Controller Unit may affect the
operation of membrane switch keypad. Extreme pressure differentials may irreversibly
damage the keypad and/or cases.
CAUTION Vents in all units should be momentarily opened and closed
immediately before use.
CAUTION Do not open a vent if there is water on or near the vent. Take
necessary precautions to ensure water does not enter the vent.
CAUTION Do not use any component that is damaged, suspected of being
damaged, or is not able to operate as designed. The safety of the operation could be