1673 OPERATION MANUAL REV A
27
3.4.14. Figure 2-11. The voltage displayed on the Remote Units should be above 350V and all
of their ARMED lights should be on.
3.4.15. On the Controller, before the arm time counter has expired, press the DISARM switch.
All Remotes will disarm within 10 seconds. The red ARMED lights will go out, and the green
READY lights will come on steady.
3.4.16. Re-arm the Controller Unit and wait for the arm time counter to expire. After expiration,
all Remote Units will return to the disarmed state. The red ARMED lights will go out, and the green
READY lights will come on steady.
3.4.17. Re-arm the Controller Unit, and before the arm time counter has expired, press both
FIRE switches together and hold for ½ second. You should notice that the test lamps light for all
Remote Units. All units subsequently return to the disarmed state. The red ARMED lights will go
out, and the green READY lights will come on steady.
3.4.18. Turn off all units. Restore test lamps, retract antennas, and close lids as required. The
system is now operationally ready for use.
3.5. TESTING THE SHOCK TUBE INITIATOR MODE
3.5.1. This test procedure must be conducted in an area that is at least 100 feet from the
nearest electric detonators or wires connected to electric detonators.
3.5.2. All RFD system components are described in detail in Section 2.
3.5.3. Ensure all units are sufficiently charged according to procedures 3.2.
3.5.4. Position the Controller and Remote Units at least 5 feet (1.5 meters) apart, in a position
where all units can be observed while testing.